Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Li, Ziheng; 1 | Wang, Linyuan; 1 | Zhang, Wenkun | Cai, Ailong | Li, Lei | Liang, Ningning | Yan, Bin; *
Affiliations: National Digital Switching System Engineering and Technological Research Centre, Zhengzhou, Henan, China
Correspondence: [*] Corresponding author: Bin Yan, National Digital Switching System Engineering and Technological Research Centre, Zhengzhou, 450002 Henan, China. E-mail: [email protected].
Note: [1] These authors contributed equally to the work.
Abstract: Total variation (TV) regularization-based iterative reconstruction algorithms have an impressive potential to solve limited-angle computed tomography with insufficient sampling projections. The analysis of exact reconstruction sampling conditions for a TV-minimization reconstruction model can determine the minimum number of scanning angle and minimize the scanning range. However, the large-scale matrix operations caused by increased testing phantom size are the computation bottleneck in determining the exact reconstruction sampling conditions in practice. When the size of the testing phantom increases to a certain scale, it is very difficult to analyze quantitatively the exact reconstruction sampling condition using existing methods. In this paper, we propose a fast and efficient algorithm to determine the exact reconstruction sampling condition for large phantoms. Specifically, the sampling condition of a TV minimization model is modeled as a convex optimization problem, which is derived from the sufficient and necessary condition of solution uniqueness for the L1 minimization model. An effective alternating direction minimization algorithm is developed to optimize the objective function by alternatively solving two sub-problems split from the convex problem. The Cholesky decomposition method is used in solving the first sub-problem to reduce computational complexity. Experimental results show that the proposed method can efficiently solve the verification problem of the accurate reconstruction sampling condition. Furthermore, we obtain the lower bounds of scanning angle range for the exact reconstruction of a specific phantom with the larger size.
Keywords: Sampling condition, limited-angle accurate reconstruction, alternating direction minimization algorithm, Cholesky decomposition method
DOI: 10.3233/XST-180455
Journal: Journal of X-Ray Science and Technology, vol. 27, no. 2, pp. 371-388, 2019
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]