Affiliations: [a] Department of Engineering Physics, Tsinghua University, Haidian District, Beijing, China | [b] Key Laboratory of Particle & Radiation Imaging (Tsinghua University) of Ministry of Education, Haidian District, Beijing, China | [c] Fudan University Shanghai Cancer Center, 270 Dongan Road, Xuhui District, Shanghai, China
Correspondence: [*] Corresponding author: Li Zhang. Room 510, Building Liuqing, Tsinghua Univeristy, Beijing, China. Tel.: +86 13910686306, E-mail: [email protected].
Abstract: BACKGROUND:Grating-based X-ray phase-contrast imaging (GPCI) has received growing interests in recent years due to its high capability of visualizing soft tissue. Breast imaging is one of the most promising candidates for the first clinical application of this imaging modality. OBJECTIVE:In this work, quantitative breast tissue characterization based on GPCI computed tomography (CT) is investigated with a laboratory X-ray tube through a comparison between attenuation-based CT images and phase-contrast CT images. METHODS:The Hounsfield units (HU) scale was introduced to phase-contrast images due to its wide application in clinical medicine. In this work, instead of water, plastic cylinders composed of polyethylene terephthalate (PET) was treated as the calibration material. An alternative test-retest reliability (TRR) was presented to evaluate the repeatability of GPCI. Comparison between attenuation-based CT imaging and GPCI CT imaging was operated with the use of statistical analysis methods like histograms and receiver operating characteristic (ROC) curves. RESULTS:The determined mean TRR related to cylinders is slightly larger in phase-contrast imaging (0.93) than that in attenuation-based imaging (0.89). With respect to distinguishing breast tissues, the AUC (area under curve) values of ROC curves of phase-contrast images are higher than that of attenuation-based images. CONCLUSIONS:An ex vivo study of GPCI shows that it is a stable imaging modality for visualizing the breast tissue with good repeatability, and that it could be of potential for the diagnosis of breast cancer as well.
Keywords: Breast imaging, phase-contrast tomography, Hounsfield units
DOI: 10.3233/XST-180453
Journal: Journal of X-Ray Science and Technology, vol. 27, no. 3, pp. 503-516, 2019
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]