Article type: Research Article
Authors: Li, Xiaoboa; 1 | Jiang, Liuqingb; 1 | Chen, Lifangc | lei, Yud | Xu, Benhuaa; * | Liu, Biyinge; * | Li, Sicongd
Affiliations: [a] Department of Radiation Oncology, Fujian Medical University Union Hospital, Fuzhou, China | [b] Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai, China | [c] Department of Radiology, Fujian Medical University Union Hospital, Fuzhou, China | [d] Department of Radiation Oncology, University of Nebraska Medical Center, Omaha, NE, USA | [e] Department of Radiology, The People’s Hospital of Fujian Traditional Chinese Medicine University, Fuzhou, China
Correspondence: [*] Corresponding authors: Benhua Xu, Department of Radiation Oncology, Fujian Medical University Union Hospital, Fuzhou 350001, China. Tel.: +8613365910602; E-mail: [email protected] and Biying Liu, Department of Radiology, The People’s Hospital of Fujian Traditional Chinese Medicine University, Fuzhou 350001, China. Tel.: +8613509333413; E-mail: [email protected].
Note: [1] Contributed equally.
Abstract: BACKGROUND:During the MRI examination, pediatric patients sleep under the sedation so that the image artifacts caused by the patient motion could be minimized. However, the sedative injection at the buttocks might cause a difficulty in the diagnosis of the buttock diseases using the MRI manifestations. OBJECTIVE:This study aims to explore the imaging characteristics of MR for the pediatric patients with the sedative injected at the buttocks in order to correctly diagnose the diseases. METHODS:MR imaging data of 64 pediatric patients injected with the sedative at the buttocks were retrospectively collected, including 8 cases of buttock disease. The imaging manifestations were analyzed and compared. RESULTS:Out of 64 patients, 8 were diagnosed as the buttock diseases. MR imaging manifestations of the sedatives injected at the buttocks were the locally patchy and streaky long T1 and long T2 signals and were different from what were shown for the normal tissues and diseases. CONCLUSION:The sedative injected at the buttocks has the MRI manifestations different from the normal tissues and diseases. Correctly understanding the MRI manifestations for the pediatric patients with the injection of sedative at the buttocks would reduce the chances of the misdiagnosis on the diseases.
Keywords: Magnetic resonance imaging, sedative, buttocks, pediatric patients
DOI: 10.3233/XST-180422
Journal: Journal of X-Ray Science and Technology, vol. 27, no. 1, pp. 73-81, 2019
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]