Authors: Lin, Jiahuia | Zhang, Haob | Huang, Jinga | Bian, Zhaoyinga | Zhang, Shanlic | Wang, Yongboa | Liao, Yutinga | Li, Suia | Zhang, Huaa | Zeng, Donga; * | Ma, Jianhuad; *
Affiliations: [a] Department of Biomedical Engineering, Guangdong Provincial Key Laborary of Medical Image Processing, Southern Medical University, Guangzhou, Guangdong, China | [b] Department of Biomedical Engineering, Johns Hopkins University, Baltimore, USA | [c] The First Affiliated Hospital of Guangzhou University of Traditional Chinese Medicine, Guangzhou, Guangdong, China | [d] Department of Biomedical Engineering, Guangzhou Key Laboratory of Medical Radiation Imaging and Detection Technology, Southern Medical University, Guangzhou, Guangdong, China
Correspondence: [*] Corresponding author: Dong Zeng, Guangdong Provincial Key Laboratory of Medical Image Processing, Department of Biomedical Engineering, Southern Medical University, Guangzhou 510515, China. E-mail: [email protected] and Jianhua Ma, Guangzhou Key Laboratory of Medical Radiation Imaging and Detection Technology, Department of Biomedical Engineering, Southern Medical University, Guangzhou 510515, China. E-mail: [email protected].
Abstract: Dual energy computed tomography (DECT) can improve the capability of differentiating different materials compared with conventional CT. However, due to non-negligible radiation exposure to patients, dose reduction has recently become a critical concern in CT imaging field. In this work, to reduce noise at the same time maintain DECT images quality, we present an iterative reconstruction algorithm for low-dose DECT images where in the objective function of the algorithm consists of a data-fidelity term and a regularization term. The former term is based on alpha-divergence to describe the statistical distribution of the DE sinogram data. And the latter term is based on the redundant information to reflect the prior information of the desired DECT images. For simplicity, the presented algorithm is termed as “AlphaD-aviNLM”. To minimize the associative objective function, a modified proximal forward-backward splitting algorithm is proposed. Digital phantom, physical phantom, and patient data were utilized to validate and evaluate the presented AlphaD-aviNLM algorithm. The experimental results characterize the performance of the presented AlphaD-aviNLM algorithm. Speficically, in the digital phantom study, the presented AlphaD-aviNLM algorithm performs better than the PWLS-TV, PWLS-aviNLM, and AlphaD-TV with more than 49%, 34%, and 40% gains for the RMSE metric, 1.3%, 0.4%, and 0.7% gains for the FSIM metric and 13%, 8%, and 11% gains for the PSNR metric. In the physical phantom study, the presented AlphaD-aviNLM algorithm performs better than the PWLS-TV, PWLS-aviNLM, and AlphaD-TV with more than 0.55%, 0.07%, and 0.16% gains for the FSIM metric.
Keywords: Dual energy computed tomography, low-dose, renconstruction, alpha-divergence, redundant information
DOI: 10.3233/XST-17272
Journal: Journal of X-Ray Science and Technology, vol. 26, no. 2, pp. 311-330, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]