Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Yazdi, Mehran; * | Mansourian, Zohre
Affiliations: Signal and Image Processing Lab., Faculty of Electrical and Computer Engineering, Shiraz University, Shiraz, Iran
Correspondence: [*] Corresponding author: Mehran Yazdi, Signal and Image Processing Lab., Faculty of Electrical and Computer Engineering, Shiraz University, Shiraz, Iran. Tel.: +98 713 6134575; Fax: +98 713 2303081; E-mail: [email protected].
Abstract: Objective of this study is to present and test a new method for metal artifact reduction (MAR) by segmenting raw CT data (sinogram). The artifact suppression technique incorporates two steps namely, metal projection segmentation in the sinogram and replacement of segmented regions by new values using an interpolation method. The proposed segmentation algorithm uses the sinogram instead of reconstructed CT slices. First, one of the best and newest region-based geometric active contour models is used to detect projection data affected by metal objects (missing projections). Then, the Hough-transform method is applied to detect all sinusoidal-like curves belonging to metal objects. Finally, a post image processing technique is used aiming to increase accuracy of the segmentation process. To provide a proof of performance, CT data of two patients with metallic teeth filling and pelvis prosthesis were included in the study as well as CT data of a phantom with metallic teeth inserts. Accuracy was determined by comparing mean, variance, mean squared error (MSE) and, peak signal to noise ratio (PSNR) as evaluation measurements of distortion in phantom images with respect to metallic teeth (original and suppressed) and without metallic teeth inserts. Quantitative results showed an average improvement of 12 dB in terms of PSNR and 517 in terms of MSE when the new MAR method was applied to remove metal artifacts. Qualitative improvement was also assessed by comparing uncorrected clinical images with artifact suppressed images. Moreover, qualitative comparison of the results of the proposed new method with the existing methods of MAR showed the superiority of the new method tested in this study.
Keywords: Active contour models, Hough transform, metal artifact reduction, sinogram
DOI: 10.3233/XST-16224
Journal: Journal of X-Ray Science and Technology, vol. 25, no. 5, pp. 737-749, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]