Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Jamsranjav, Erdenetogtokha; * | Kuge, Kenichia | Ito, Atsushib | Kinjo, Yasuhitoc | Shiina, Tatsuoa
Affiliations: [a] Graduate School of Advanced Integration Science, Chiba University, Chiba-shi, Chiba, Japan | [b] School of Engineering, Tokai University, Hiratsuka-shi, Kanagawa, Japan | [c] Tokyo Metropolitan Industrial Technol. Res. Inst., Koto-ku, Tokyo, Japan
Correspondence: [*] Corresponding author: Erdenetogtokh Jamsranjav, Graduate School of Advanced Integration Science, Chiba University, Chiba-shi, Chiba 263-8522, Japan. Tel./Fax: +81 43 290 3470; E-mail: [email protected].
Abstract: Soft X-ray microscopy has been developed for high resolution imaging of hydrated biological specimens due to the availability of water window region. In particular, a projection type microscopy has advantages in wide viewing area, easy zooming function and easy extensibility to computed tomography (CT). The blur of projection image due to the Fresnel diffraction of X-rays, which eventually reduces spatial resolution, could be corrected by an iteration procedure, i.e., repetition of Fresnel and inverse Fresnel transformations. However, it was found that the correction is not enough to be effective for all images, especially for images with low contrast. In order to improve the effectiveness of image correction by computer processing, we in this study evaluated the influence of background noise in the iteration procedure through a simulation study. In the study, images of model specimen with known morphology were used as a substitute for the chromosome images, one of the targets of our microscope. Under the condition that artificial noise was distributed on the images randomly, we introduced two different parameters to evaluate noise effects according to each situation where the iteration procedure was not successful, and proposed an upper limit of the noise within which the effective iteration procedure for the chromosome images was possible. The study indicated that applying the new simulation and noise evaluation method was useful for image processing where background noises cannot be ignored compared with specimen images.
Keywords: Soft X-ray, projection microscopy, iteration procedure, noise evaluation
DOI: 10.3233/XST-16201
Journal: Journal of X-Ray Science and Technology, vol. 25, no. 4, pp. 653-665, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]