Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Kang, W.G.a; * | Pyo, S.H.a | Alkhuraiji, T.S.b | Han, B.S.a | Kang, C.M.a
Affiliations: [a] EB Tech Co., Ltd., 170-9, Techno 2-ro, Yuseong-gu, Daejeon, Republic of Korea | [b] King AbdulAziz City for Science & Technology (KACST), Riyadh, Kingdom of Saudi Arabia
Correspondence: [*] Corresponding author: W.G. Kang, EB Tech Co., Ltd., 170-9, Techno 2-ro, Yuseong-gu, Daejeon, 34028, Republic of Korea. Tel.: +82 42 9307506; Fax: +82 42 9307500; E-mail: [email protected].
Abstract: The King AbdulAziz City for Science & Technology in the Kingdom of Saudi Arabia plans to build a 10 MeV, 15 kW linear accelerator (LINAC) for electron beam and X-ray. The accelerator will be supplied by EB Tech, Republic of Korea, and the design and construction of the accelerator building will be conducted in the cooperation with EB Tech. This report presents the shielding analysis of the accelerator building using the Monte Carlo N-Particle Transport Code (MCNP). In order to improve the accuracy in estimating deep radiation penetration and to reduce computation time, various variance reduction techniques, including the weight window (WW) method, the deterministic transport (DXTRAN) spheres were considered. Radiation levels were estimated at selected locations in the shielding facility running MCNP6 for particle histories up to 1.0×10+8. The final results indicated that the calculated doses at all selected detector locations met the dose requirement of 50 mSv/yr, which is the United State Nuclear Regulatory Commission (U.S. NRC) requirement.
Keywords: Monte Carlo transport, MCNP, electron linear accelerator, radiation shielding, occupational dose limit, variance reduction
DOI: 10.3233/XST-16196
Journal: Journal of X-Ray Science and Technology, vol. 25, no. 3, pp. 505-514, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]