Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Chen, Chun-Youa | Lee, Liang-Mingb | Yu, Hsiao-Weic | Lee, Steve P.d | Lee, Hsin-Lunc | Lin, Yung-Weib | Wen, Yu-Chingb | Chen, Yi-Jua | Chen, Chiu-Pinga | Tsai, Jo-Tinge; *
Affiliations: [a] Department of Radiation Oncology, Wan Fang Hospital, Taipei Medical University, Taipei, Taiwan | [b] Department of Urology, Wan Fang Hospital, Taipei Medical University, Taipei, Taiwan | [c] Department of Radiation Oncology, Taipei Medical University Hospital, Taipei, Taiwan | [d] Department of Radiation Oncology, University of California, Los Angeles, CA, USA | [e] Department of Radiation Oncology, Shuang Ho Hospital, Taipei Medical University, Taipei, Taiwan
Correspondence: [*] Corresponding author: Jo-Ting Tsai, Department of Radiation Oncology, Shuang Ho Hospital, Taipei Medical University, No. 291, Zhongzheng Rd., Zhonghe District, New Taipei City, Taiwan 23561, Taiwan(R.O.C.). Tel.: +886 2 22490088#1352; Fax: +886 2 22490088#1369; E-mail: [email protected].
Abstract: BACKGROUND AND PURPOSE: As recent studies have suggested relatively low α/β for prostate cancer, the interest in hypofractionated stereotactic body radiotherapy (SBRT) for prostate cancer is rising. The aim of this study is to compare dosimetric results of Cyberknife (CK) with Tomotherapy (HT) in SBRT for localized prostate cancer. Furthermore, the radiobiologic consequences of heterogeneous dose distribution are also analyzed. MATERIAL AND METHOD: A total of 12 cases of localized prostate cancer previously treated with SBRT were collected. Treatments had been planned and delivered using CK. Then HT plans were generated for comparison afterwards. The prescribed dose was 37.5Gy in 5 fractions. Dosimetric indices for target volumes and organs at risk (OAR) were compared. For radiobiological evaluation, generalized equivalent uniform dose (gEUD) and normal tissue complication probability (NTCP) were calculated and compared. RESULT: Both CK and HT achieved target coverage while meeting OAR constraints adequately. HT plans resulted in better dose homogeneity (Homogeneity index: 1.04±0.01 vs. 1.21±0.01; p = 0.0022), target coverage (97.74±0.86% vs. 96.56±1.17%; p = 0.0076) and conformity (new vonformity index: 1.16±0.05 vs. 1.21±0.04; p = 0.0096). HT was shown to predict lower late rectal toxicity as compared to CK. Integral dose to body was also significantly lower in HT plans (46.59±6.44 Gy’L vs 57.05±11.68 Gy’L; p = 0.0029). CONCLUSION: Based on physical dosimetry and radiobiologic considerations, HT may have advantages over CK, specifically in rectal sparing which could translate into clinical benefit of decreased late toxicities.
Keywords: Stereotactic body radiation therapy (SBRT), prostate cancer, equivalent uniform dose (EUD), normal tissue complication probability (NTCP), cyberknife, tomotherapy
DOI: 10.3233/XST-16169
Journal: Journal of X-Ray Science and Technology, vol. 25, no. 3, pp. 465-477, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]