Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Mory, Cyril | Auvray, Vincent | Zhang, Bo | Grass, Michael | Schäfer, Dirk | Rit, Simon | Peyrin, Françoise; | Douek, Philippe | Boussel, Loïc
Affiliations: Université de Lyon, CREATIS, INSA-Lyon, Université Lyon 1, Villeurbanne Cedex, France | Philips Research Medisys, Suresnes, France | Philips Research, Röntgenstrasse, Hamburg, Germany | Université de Lyon, CREATIS, Lyon, France | X-ray Imaging Group, European Synchrotron, Radiation Facility, BP, Grenoble Cedex, France | Université de Lyon, CREATIS, INSA-Lyon, Université Lyon 1, Hospices Civils de Lyon, Lyon, France
Note: [] Corresponding author: Cyril Mory, Université de Lyon, CREATIS; CNRS UMR5220; Inserm U1044; INSA-Lyon; Université Lyon 1; F-69621 Villeurbanne Cedex, France. Tel.: +33 472 357 412; E-mail: [email protected]
Abstract: BACKGROUND: 4D cardiac computed tomography aims at reconstructing the beating heart from a series of 2D projections and the simultaneously acquired electrocardiogram. Each cardiac phase is reconstructed by exploiting the subset of projections acquired during this particular cardiac phase only. In these conditions, the Feldkamp, Davis and Kress method (FDK) generates large streak artifacts in the reconstructed volumes, hampering the medical interpretation. These artifacts can be substantially reduced by deconvolution methods. OBJECTIVE: The aim of this paper is to compare two 4D cardiac CT reconstruction methods based on deconvolution, and to evaluate their practical benefits on two applications: cardiac micro CT and human cardiac C-arm CT. METHODS: The first evaluated method builds upon inverse filtering. It has been proposed recently and demonstrated on 4D cardiac micro CT. The second one is an iterative deconvolution method, and turns out equivalent to an ECG-gated Iterative Filtered Back Projection (ECG-gated IFBP). RESULTS: Results are presented on simulated data in 2D parallel beam, 2D fan beam and 3D cone beam geometries. CONCLUSIONS: Both methods are efficient on the cardiac micro CT simulations, but insufficient to handle 4D human cardiac C-Arm CT simulations. Overall, ECG-gated IFPB largely outperforms the inverse filtering method.
Keywords: C-Arm, computed tomography, cardiac, electrocardiogram, 4D, deconvolution, iterative FBP, inverse filtering, micro CT
DOI: 10.3233/XST-140423
Journal: Journal of X-Ray Science and Technology, vol. 22, no. 2, pp. 253-270, 2014
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]