Article type: Research Article
Authors: Qin, Zhuanping | Cui, Shanshan | Zhao, Huijuan; | Zhou, Xiaoqing | Jia, Mengyu | Yang, Yanshuang | Fan, Ying | Gao, Feng;
Affiliations: College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin, China | Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin, China
Note: [] Corresponding author: Huijuan Zhao, College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China. Tel.: +86 022 27404209; Fax: +86 022 27404209; E-mail: [email protected]
Abstract: Endoscopic diffuse optical tomography (DOT) is a new medical imaging modality with the potential applications in functional imaging of the internal organs. To cut down the measurement time and the computation burden of image reconstruction, in this paper, we developed the image reconstruction algorithm with the partial measurement in the effective detection range (EDR) of a tubular tissue and the corresponding endoscopic imaging system with a novel endoscopic probe for flexibly selecting the detection sites. For a typical inner size and optical properties of the cervix, it is found that EDR is less than half of the inner circumference. Comparing to the traditional method, the adoption of EDR results in a reduction of more than a factor of two in the time cost for a measurement cycle and for the total iteration reconstruction. Images reconstructed from the simulation data demonstrate that the proposed method achieves equivalent image quality to that obtained from the complete data set. The images reconstructed from the EDR measurements on cervix-like solid phantoms show that both the location and size of the targets are reconstructed correctly. The proposed method will be useful to the development of endoscopic DOT technologies for cancer detection in tubular organs including cervix.
Keywords: Endoscopic diffuse optical tomography, partial measurement, effective detection range, frequency-domain, image reconstruction algorithm
DOI: 10.3233/XST-130397
Journal: Journal of X-Ray Science and Technology, vol. 21, no. 4, pp. 527-543, 2013
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]