Article type: Research Article
Authors: Shih, Tzu-Ching | Lin, Yang-Hsien; | Ho, Yung-Jen | Hsiao, Hung-Da; | Huang, Yung-Hui | Huang, Tzung-Chi
Affiliations: Department of Biomedical Imaging and Radiological Science, China Medical University, Taiwan, China | Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, Taiwan, China | National Center for High-Performance Computing, Hsinchu, Taiwan, China | Power Mechanical Engineering Department, National Tsing Hua University, Taiwan, China | Department of Medical Imaging and Radiological Sciences, I-Shou University, Taiwan, China
Note: [] Corresponding author: Tzung-Chi Huang, Department of Biomedical Imaging and Radiological Science, China Medical University, Taiwan 91, Hsueh-Shih Road, Taichung City, Taiwan 404, China. Tel.: +886 422 053 366 # 7805; E-mail: [email protected]
Abstract: Background and purpose: Computational fluid dynamics method (CFDM) and optical flow method (OFM) effectively provide the hemodynamic information based on the digital subtraction angiogram (DSA). However, the quantitative analysis in comparison of CFDM and OFM is still absent. The goal of this study is to apply CFDM and OFM in quantitative analysis of stenting treatment. Material and method: A left carotid stenosis patient underwent stenting of percutaneous transluminal angioplasty was analyzed as an example. CFDM and OFM for hemodynamic analysis on digital subtraction angiography before and after stenting treatment were presented. Results: Improvement gains of blood flow velocities on left internal carotid artery after stenting treament for different initial conditions on the common carotid artery were 1.91 ∼ 2.13, 1.62 ∼ 2.09, and 0.69 by CFDM with Newtonian and non-Newtonian fluids and OFM, respectively. With the CFDM analysis, the flow mapping by OFM using time resolved DSA data on the fly to estimate hemodynamic significance of a cervical carotid stenosis was explained. Conclusion: Quantificative blood flow estimations by CFDM and OFM to evaluate the treatment outcomes to patient with carotid stenosis are practical. Both methods are able to provide quantitative information of blood flow for stenting treatment. It is advantagious to use both methods in treatment evaluation.
Keywords: Stenosis, angiography, computational fluid dynamics method, optical flow method
DOI: 10.3233/XST-2012-00353
Journal: Journal of X-Ray Science and Technology, vol. 20, no. 4, pp. 469-481, 2012
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]