Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Fu, Jianwei; | Yang, Xiaoquan; | Meng, Yuanzheng; | Luo, Qingming; | Gong, Hui;
Affiliations: Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics-Huazhong University of Science and Technology, Wuhan, Hubei, China | Key Laboratory of Biomedical Photonics of Ministry of Education, Huazhong University of Science and Technology, Wuhan, Hubei, China
Note: [] Corresponding author: Hui Gong, Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics-Huazhong University of Science and Technology, 1037 Luoyu Road, Wuhan 430074, Hubei, China. E-mail: [email protected]
Abstract: The combined system of micro-CT and fluorescence molecular tomography (FMT) offers a new tool to provide anatomical and functional information of small animals in a single study. To take advantages of the combined system, a data preprocessing method is proposed to extract the valid data for FMT reconstruction algorithms using a priori information provided by CT. The boundary information of the animal and animal holder is extracted from reconstructed CT volume data. A ray tracing method is used to trace the path of the excitation beam, calculate the locations and directions of the optional sources and determine whether the optional sources are valid. To accurately calculate the projections of the detectors on optical images and judge their validity, a combination of perspective projection and inverse ray tracing method are adopted to offer optimal performance. The imaging performance of the combined system with the presented method is validated through experimental rat imaging.
Keywords: Micro-CT, fluorescence molecular tomography, multi-modal imaging, data preprocessing
DOI: 10.3233/XST-2012-00352
Journal: Journal of X-Ray Science and Technology, vol. 20, no. 4, pp. 459-468, 2012
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]