Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Cai, Zhijun | Bai, Er-Wei | Wang, Ge | Sharafuddin, Melhem J. | Abada, Hicham T.
Affiliations: Department of Electrical and Computer Engineering, University of Iowa, Iowa City, IA, USA | VT-WFU School of Biomedical Engineering & Sciences, Virginia Polytechnic Institute & State University, Blacksburg, VA, USA | University of Iowa Hospital and Clinic, Iowa City, IA, USA
Note: [] Corresponding author: Er-Wei Bai, PhD, Departments of Electrical and Computer Engineering, University of Iowa, Iowa City, IA 52242, USA. E-mail: [email protected]
Abstract: Computed Tomography (CT) has become an effective diagnosis and evaluating tool in clinical; however, its radiation exposure has drawn great attention as more and more CT scans are performed every year. How to reduce the radiation dose and meanwhile keep the resultant CT images diagnosable becomes an important research topic. In this paper, we propose a dose reduction approach along with the adaptive bolus chasing CT Angiography (CTA) techniques, which are capable of tracking the contrast bolus peak over all the blood vessel segments during the CTA scan. By modulating the tube current (and collimator width) online, we can reduce the total radiation dose and maintain the contrast to noise ratio (CNR) of the blood vessel. Numerical experiments on reference DSA data sets show that by using the proposed dose reduction method, the effective radiation dose can be saved about 39%.
Keywords: Radiation exposure, dose reduction, computed tomography, computed tomography angiography (CTA), contrast to noise ratio (CNR), adaptive bolus chasing
DOI: 10.3233/XST-2010-0236
Journal: Journal of X-Ray Science and Technology, vol. 18, no. 1, pp. 15-25, 2010
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]