Abstract: Computed microtomography (μCT) is an imaging technique that produces virtual slices of an object, based on a set of x-ray images taken while the object is stepwise rotated. The stack of slices is calculated with a backprojection algorithm, it demands that the entire object remains within the x-ray beam for all observed angles. During region-of-interest (ROI) tomography however, one zooms in on a small part of the object. As a consequence the above condition is no longer fulfilled; the input data become incomplete and reconstructed slices are corrupted. In this study we show that, if we are not interested in grayscale values but only in geometrical information, conventional backprojection algorithms still perform well for ROI tomography. We demonstrate this with ROI scans performed on several phantom objects and we show ROI images of the gerbil hearing organ. We found that the resolution could considerably be improved and small details, not visible in a conventional full object scan, can be revealed by a ROI scan. One can use the benefits of ROI-μCT in situations where physical constrains are such that large parts of the object exceed the field of view (FOV), or where a very high magnification is required.
Keywords: Microtomography, region of interest, temporal bone, middle ear
Journal: Journal of X-Ray Science and Technology, vol. 13, no. 3, pp. 137-147, 2005
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]