Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Nagabhushan, N.M. | Kerur, B.R. | Lagare, M.T. | Nathuram, R. | Abani, M.C. | Thontadarya, S.R. | Hanumaiah, B.
Affiliations: Department of Physics, Gulbarga University, Gulbarga-585 106, India | Radiation Safety System Division, Radiation Standards Section, Mumbai-400 085, India | Department of Physics, Karnatak University, Dharwad-580 003, India | Mangalore University, Mangalore-577 149, India
Note: [] Corresponding author: Tel.: +91 8472 446639; Fax: +91 8472 422039; E-mail: [email protected]
Abstract: A new and accurate method to determine the mass attenuation coefficient, μm, for low photon energy employing NaI(Tl) X-ray detector and radioactive source is described. Effect of size of collimator and the selection of width of photopeak for integration on the contribution from scattered photons to the transmitted intensity is studied systematically and optimum size of collimator and photopeak limits for integration are established. With a 6 mm diameter collimator and FWHM for photopeak limits it was found that Beer-Lambert's law was rigorously valid over transmission range of 50–2%. Using this method μm was determined for six elements that covered a wide atomic number range (12 < Z < 73) and two biological equivalent materials. The values so obtained agreed with theoretical values within 1% establishing the validity and accuracy of the present method which uses inexpensive moderate resolution detector. As the method permits higher transmission range better counting statistics is an added advantage.
Keywords: X-ray attenuation coefficient, X-ray cross section, X-rays
Journal: Journal of X-Ray Science and Technology, vol. 12, no. 3, pp. 161-168, 2004
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]