Article type: Research Article
Authors: Ye, Chang | Luo, Qingming | Chen, Wei R. | Liang, Wenxi | Luo, Weihua | Zhong, Aijun
Affiliations: The Key Laboratory of Biomedical Photonics of Ministry of Education Huazhong University of Science and Technology, Wuhan, 430074, China | Department of Physics and Engineering, University of Central Oklahoma, Edmond, OK 73034, USA
Note: [] Corresponding author: Prof. Qingming Luo. Tel.: +86 27 87464580; Fax: +86 27 87464570; E-mail: [email protected]
Abstract: The thickness of the surrounding tissue is a crucial factor in distinguishing the internal blood vessels in digital X-ray images, because enough contrast between vessels and tissues must be generated. We investigated the X-ray attenuations of fat, liver, and muscle tissues, using a digital X-ray imaging system specially designed for small animal studies and the contrast between these tissues and blood vessels. The fat, muscle and the liver tissues were collected from the abdomen, the back and the liver of an adult crossbred swine, respectively. The blood vessels were from mesentery of a Wistar rat. The attenuation coefficients of different tissues and blood vessels of different sizes were measured under different X-ray exposures. Also quantified was the contrast between the tissues and the blood vessels when the diameter of the blood vessel and the thickness of the tissues were the same. The limiting thickness of various tissues at different X-ray exposures was obtained for detecting internal blood vessels of a given size, using the CCD detecting limit, the contrast resolution of the imaging system and the tissue-vessel configuration. The results provided herein could be used for optimization of the parameters of digital X-ray imaging in detecting internal blood vessels.
Keywords: digital X-ray imaging, charge-coupled device (CCD), small blood vessel, image contrast, detection limitation
Journal: Journal of X-Ray Science and Technology, vol. 12, no. 2, pp. 59-71, 2004
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]