Abstract: It is of interest to know the minimum discernible detail size when performing non-destructive testing with high-resolution computerised tomography. But it is difficult to empirically find optimal parameter settings that maximise detectability for each individual imaging task. In this work a method to determine the optimal performance for a high-resolution computerised tomography system has been developed. It reveals the detectability limit for specific contrasting details in terms of imaged object diameter when the signal-to-noise ratio, SNRδS,CT, between the contrasting detail and its surroundings has been maximised using optimal data collection parameter settings. This work includes modelling and verification of the total unsharpness of the CT-system in terms of modulation transfer-function, MTF. Together with the limiting perception factor and maximised SNRδproj in the CT projection data, the detectability limits for any specific contrasting detail are determined as a function of imaged object material and geometry. Maximised SNRδproj was obtained by optimising the parameters: X-ray source tube potential, X-ray filter, exposure time and optical aperture. The importance of using optimal settings when performing CT-investigations, especially when investigating objects with large diameters, is demonstrated. It was found that it is possible to predict the detectability for any specific contrasting detail. It was also discovered that the optimal settings for a given object diameter and material are dependent on the detail material. In some cases an improvement of the detail signal-to-noise-ratio was obtained by using a combination of X-ray filter materials. It was also found that SNRδproj is very sensitive to the thickness of denser X-ray filter materials (higher atomic number and density).
Keywords: Computerised tomography, CT, detectability, optimal performance
Journal: Journal of X-Ray Science and Technology, vol. 8, no. 1, pp. 51-73, 1998
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]