Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Juneja, Hemanta; * | Frandsen, Christianb | Nielsen, Nina Odgaarda | Larsen, Kima | Praestegaard, Jeanettea
Affiliations: [a] University College Absalon, Center of Nutrition and Rehabilitation Roskilde, Denmark | [b] University College Copenhagen, Department of Physiotherapy, Hilleroed, Denmark
Correspondence: [*] Corresponding author: Hemant Juneja, University College Absalon, Center of Nutrition and Rehabilitation, Trekroner Forskerpark 4, Roskilde 4000, Denmark. E-mail: [email protected].
Abstract: PURPOSE:The Wii Balance Board (WBB) can be used for assessment of steady state balance (SSB), but its reliability has not been studied in children aged 6–9 years. This study aimed to determine the test-retest reliability of the WBB for measuring SSB in this population. A secondary aim was to determine the minimum detectable change (MDC) and standard error of measurement (SEM) of the WBB in children aged 6–9 years. METHODS:52 children between 6–9 years of age participated. “One leg stand balance” was used to assess center of pressure velocity (COPV) and center of pressure area (COPA) on three occasions by the same tester. Two tests were conducted on the same day (Day 1) and the third test was performed on another day (Day 2), with a period of 5–13 days between the two test days. Intraclass correlation coefficient (ICC 3,1), SEMs, and MDC were calculated. RESULTS:Intra-day test-retest reliability of COPA was found to be good (ICC3,1 =0.86; 95% confidence interval [CI]: 0.75, 0.92) and that of COPV was also found to be good (ICC3,1 =0.87; 95% CI: 0.77, 0.92). Inter-day test-retest reliability was found to be good for COPA (ICC3,1 = 0.87; 95% CI: 0.75, 0.93) and COPV (ICC3,1 = 0.89; 95% CI: 0.81, 0.94). SEM for COPA in intra-day testing was 18.90 mm2 (15.78%), and in inter-day testing it was 16.44 mm2 (13.61%). SEM for COPV in intra-day testing was 1.12 mm/s (7.6%), and in inter-day testing it was 1.01 mm/s (6.9%). MDC for COPA in intra-day testing was 52.41mm2 (42.75%), and in inter-day testing was 45.58 mm2 (35.75%). MDC for COPV in intra-day testing was 3.11 mm/s (21.2%), and in inter-day testing it was 2.80 mm/s (18.9%). CONCLUSION:The WBB has good test-retest reliability for assessing SSB of children between 6-9 years. COPA measurements appear to be less sensitive to clinical changes in SSB when compared to COPV. Assessment of validity of the WBB in this age group is recommended before it can be considered as a potential balance assessment tool in children.
Keywords: Wii Balance Board, center of pressure, reliability, steady state balance
DOI: 10.3233/PRM-210106
Journal: Journal of Pediatric Rehabilitation Medicine, vol. 16, no. 2, pp. 369-380, 2023
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]