Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Bishnoi, Saroja; * | Sarkar, P.S.a | Shukla, Mayanka | Ray, Nirmala | Patel, Taruna | Kashyap, Yogesha | Roy, Tushara | Adhikari, P.S.a | Pal, Manoja | Sinha, Amarb
Affiliations: [a] Technical Physics Division, Bhabha Atomic Research Center, Mumbai, India | [b] Bhabha Atomic Research Center, Mumbai, India
Correspondence: [*] Corresponding author. E-mail: [email protected].
Abstract: Accurate neutron flux mapping of reactors and neutron generators is important from the point of view of determining system characteristics. In these applications, the flux measurement with high spatial resolution and in very narrow spaces is required such as in between fuel rods assemblies or shielding materials. In this paper, we describe the design and development of high spatial resolution (∼mm) fiber-based detectors for neutron flux mapping in a typical subcritical assembly – BRAHMMA. These detectors utilize neutron convertor-scintillator coupled to the tip of an optical fiber at one end with its other end coupled to a photomultiplier tube. We have used scintillators such as 6LiF+ZnS (Ag) for thermal neutrons and ThO2+ZnS (Ag) for fast neutrons. The detectors were calibrated for 3×10−4cps and 3.6×10−6cps per unit neuron flux of thermal and fast neutron respectively. Small size (∼mm) of these detectors is well suited for measurement of thermal neutron flux profile in narrow experimental channels of the subcritical assembly BRAHMMA. The measured thermal neutron flux profile was compared with those obtained from a miniature 3He detector used in the past. Periodic variation in the flux profile has been observed at the fuel lattice positions of the subcritical assembly, which was not observed with the 3He detector. We also present a neutron emission profile measurement of a D-T neutron generator using the developed fast neutron detector.
Keywords: High spatial resolution detector, flux mapping in subcritical system, D-T neutron generator
DOI: 10.3233/JNR-170045
Journal: Journal of Neutron Research, vol. 19, no. 3-4, pp. 169-175, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]