Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Sochala, Maximiliena; 1 | Wahbi, Karima; b; 1; * | Sorbets, Emmanuelc | Lazarus, Arnaudd | Bécane, Henri-Marcb | Stojkovic, Tanyab | Fayssoil, Abdallahb | Laforêt, Pascalb; e | Béhin, Anthonyb | Sroussi, Marjoriea | Eymard, Brunob; e | Duboc, Denisa; b | Meune, Christophec
Affiliations: [a] Department of Cardiology, AP-HP, Cochin Hospital, Paris Descartes University, Paris, France | [b] AP-HP, Pitié-Salpêtrière Hospital, Myology Institute, Paris, France | [c] Department of Cardiology, AP-HP, Avicenne Hospital, Bobigny, France; Paris XIII University, Bobigny, France | [d] InParys Clinical Research Associates, Saint Cloud, Paris, France | [e] Pierre and Marie Curie University, Paris, France
Correspondence: [*] Correspondence to: Karim Wahbi, MD, PhD, Department of Cardiology, Cochin Hospital, 27 rue du Faubourg Saint Jacques, 75679 PARIS Cedex 14, France. Tel.: +33 1 58 41 16 53; Fax: +33 1 58 41 16 66; E-mail: [email protected].
Note: [1] These two authors contributed equally to this work.
Abstract: Background:Pacemakers (PM) and implantable cardioverter defibrillators (ICD) may be indicated for sudden death prevention in myotonic dystrophy type 1 (DM1), however the risk of complications after the placement of these devices is unknown. Objective:To compare the rate of device-related complications between PM and ICD implantations in patients with DM1. Methods:Among 914 patients with DM1 included in the DM1 Heart Registry between January 2000 and January 2010, we retrospectively selected 23 patients who were implanted with an ICD and matched them to 46 controls with a PM on age, gender, and year of device placement. Results:Over a 6 years follow-up period, we observed device-related complications in 9 ICD recipients (inappropriate shocks in 5, lead dysfunction in 5, infection in 2) and in 3 PM recipients (lead dysfunction in 3). Patients with an ICD had, compared to those with a PM, higher rates of complications (39.1% vs. 6.5%, p = 0.0006) and more frequent complications requiring hospitalisation and/or re-intervention (respectively 30.4% and 21.7% vs. 0%). Conclusion:Our study shows a higher risk of device-related complications after the implantation of an ICD than for a PM in patients presenting with DM1.
Keywords: Myotonic dystrophy 1, complications, implantable cardioverter-defibrillator, pacemaker
DOI: 10.3233/JND-170232
Journal: Journal of Neuromuscular Diseases, vol. 4, no. 3, pp. 175-181, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]