Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Garland, J.S. | Alex, C.P. | Johnston, N. | Yan, J.C. | Werlin, S.L.
Affiliations: Department of Pediatrics, Wheaton Franciscan Healthcare-St Joseph Hospital, Milwaukee, WI, USA | Department of Otolaryngology and Communication Sciences, Medical College of Wisconsin, Milwaukee, WI, USA | Department of Pediatrics, Division of Gastroenterology, Medical College of Wisconsin, Milwaukee, WI, USA
Note: [] Corresponding author: Dr. Jeffery S. Garland, 5206 W River Trails Court, Mequon, WI 53092, USA. Tel.: +1 414 447 2674; Fax: +1 414 447 2884; E-mail: [email protected]
Abstract: OBJECTIVES: To determine the frequency of tracheal pepsin in ventilated neonates and whether the angle of head elevation was associated with tracheal pepsin. STUDY DESIGN: Serial trachael samples (at 3, 7, 14, 21 and 28 days of ventilation) were obtained from intubated, ventilated very low birth weight infants. Presence of tracheal pepsin was determined by Western blot analysis using a specific anti-human pepsin antibody. RESULTS: Tracheal pepsin was detected in 35/66 (53%) of the ventilated neonates (birthweight: 798 ± 268 grams [mean ± standard deviation]). Neonates whose head elevation was in the upper quartile (≥14 degrees) during the first sampling time (day 3) were less likely (4/16 vs 9/10, P = 0.0013) to have tracheal pepsin when compared to neonates whose head elevation was in the lowest quartile (≤8 degrees). CONCLUSIONS: Pepsin, a marker for gastric secretion aspiration, was detected in 53% of ventilated low birth weight neonates; early elevation of the head of the bed was associated with a lower rate of tracheal pepsin.
Keywords: Aspiration, ventilator associated pneumonia, very low birth weight infants, gastroesophageal reflux
DOI: 10.3233/NPM-14814020
Journal: Journal of Neonatal-Perinatal Medicine, vol. 7, no. 3, pp. 185-192, 2014
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]