Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Said, M.M. | Niforatos, N. | Rais-Bahrami, K.
Affiliations: Department of Neonatology, Children's National Medical Center, and the George Washington University School of Medicine, Washington, DC, USA
Note: [] Corresponding author: Dr. Mariam M. Said, Department of Neonatology, Children's National Medical Center, 111 Michigan Avenue, NW, Washington, DC 20010, USA. Tel.: +1 202 476 5448; Fax: +1 202 476 3459; E-mail: [email protected]
Abstract: Objective: Simultaneous monitoring of cerebral and mesenteric tissue saturations were recorded in preterm neonates using near infrared spectroscopy (NIRS) to evaluate if NIRS method can be improved to compensate for the optical absorption properties of stool interference, particularly meconium and transitional stools, in order to reliably measure gastrointestinal (GI) tissue oxygen saturation. Study design: With parental agreement, we used a 4-wavelength cerebral & tissue oximeter (FORE-SIGHT®, CAS Medical Systems, Branford, CT USA) to monitor premature neonates. The NIRS sensors were placed in the right lower quadrant of the abdomen and the forehead, with continuous data collection every 2 seconds for 72 hours. Simultaneously, continuous peripheral pulse oximetry (SpO2) was recorded. Feeding regimens, stooling patterns and clinical outcomes were recorded. Raw data from FORE-SIGHT were recorded and analyzed using a prototype neonatal stool compensation algorithm. Results: Twenty-three preterm neonates with adjusted gestational ages of 26–34 weeks, weighing 740–1930 grams were studied. NIRS stool interference level was determined for all subjects, and found to be extremely variable. High and Very High stool interference occurred for subjects passing meconium. Moderate and High stool interference resulted in erroneously computed very low GI StO2 using traditional NIRS methods. Stool compensated GI StO2 measurements showed a higher correlation to cerebral SctO2 and pulse oximetry SpO2 in subjects with healthy bowel. Conclusion: Measurement of mesenteric saturations via NIRS proves to be a useful tool in neonates. A NIRS algorithm that compensates for interference caused by meconium and transitional stools shows promising results to measure GI StO2 accurately.
Keywords: NIRS, mesenteric saturation, meconium, NEC
DOI: 10.3233/NPM-2012-53311
Journal: Journal of Neonatal-Perinatal Medicine, vol. 5, no. 1, pp. 9-16, 2012
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]