Article type: Research Article
Authors: Adu-Amankwa, N.A. | Rais-Bahrami, K.
Affiliations: Departments of Neonatology Children's National Medical Center and The George Washington University School of Medicine, Washington, DC, USA
Note: [] Corresponding author: K. Rais-Bahrami, Department of Neonatology, Children's National Medical Center, 111 Michigan Avenue, N.W., Washington, DC 20010-2970, USA. Tel.: +1 202 476 4683; Fax: +1 202 476 3459; E-mail: [email protected]
Abstract: Objective: Each year thousands of preterm and sick infants are admitted to neonatal intensive care units (NICU) requiring continuous cardio respiratory monitoring. A new and innovative wireless monitor was evaluated which incorporates two unique non invasive electrodeless sensors for the detection of respiration and cardiac waveforms. The objective of the study was to determine if the sensors used by the wireless Monitor (PGS Medical Research and Electronic Design, LLC, Fairfield, CT) provide equal performance for data acquisition compared to reference monitors. A further objective was to evaluate the potential ease of application and lack of wires offered by this technology in the NICU. Methods: After approval from the Institutional Review Board (IRB) and obtaining parental consent, 25 patients were enrolled in the study. The wireless sensor belt was then placed around the abdomen. Breathing and heart rate waveform were recorded from the wireless research monitor and from the existing NICU equipment (reference monitor) for a total of 90 minutes. Results: Waveform data was recorded on a 4 channel analog Windaq system. Each file was then reviewed and 5 selections of at least 3 minutes duration wherein both monitors were displaying stable waveforms were compared for parity of peaks representing a beat. Manually counting the peaks showed a 96% correspondence with standard deviation of ± 2 beats discrepancy between the two monitors. Conclusion: The data from the study supports the wireless/electrodeless monitor as an effective method to collect cardio respiratory data in the NICU patient population.
Keywords: Neonates, intensive care, wireless monitor
DOI: 10.3233/NPM-2011-51311
Journal: Journal of Neonatal-Perinatal Medicine, vol. 4, no. 4, pp. 329-332, 2011
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]