Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Cordero, L.; | Nankervis, C.A. | Coley, B.D.; | Giannone, P.J.
Affiliations: Department of Pediatrics, The Ohio State University Medical Center, Columbus, OH, USA | Department of Obstetrics, The Ohio State University Medical Center, Columbus, OH, USA | Department of Radiology, The Ohio State University Medical Center, Columbus, OH, USA
Note: [] Corresponding author: Leandro Cordero, Division of Neonatal-Perinatal Medicine, Department of Pediatrics, The Ohio State University Medical Center, N118 Doan Hall, 410 W. 10th Avenue, Columbus, OH 43210 1228, USA. Tel.: +1 614 293 8660; Fax: +1 614 293 7676; E-mail: [email protected]
Abstract: Background: Traditionally, orogastric tube (OGt) insertion length is determined by nose-earlobe-xyphoid (NEX) measurement. Minimum insertion lengths have been proposed for prematures but not for extremely low birth weight (ELBW) infants. Objective: To determine minimum OGt insertion length for intragastric placement in ELBW infants using NEX measurements alone and NEX measurements in conjunction with a novel regression formula. Design/Methods: Retrospective phase (83 pts): Correct intragastric placements were identified and a regression formula for predicting insertion length was created. Prospective phase (50 pts): Nurses were instructed to use NEX measurements if they coincided within 1 cm with estimates from the regression formula (birth weight g × 0.004 + 9.44 = cm insertion length). In cases of discrepancy, measurements calculated by the formula were used. Results: Using NEX method alone, the first OGt placements were in the esophagus (6%) straight in the stomach (6%), reversed in the stomach (4%), in the duodenum (1%) and “correctly” placed diagonal in the stomach (83%). Using NEX measurement and the regression formula, OGt placements were diagonal in the stomach (96%), or straight in the stomach (4%), with none in the esophagus, reversed in the stomach or in the duodenum. The difference in correct placements by the two methods was significant. Conclusions: NEX measurements in conjunction with a minimum insertion length estimated from a formula should decrease the number of malpositioned OGt in ELBW infants.
Keywords: Orogastric, feeding tube, premature infants
DOI: 10.3233/NPM-2011-2717
Journal: Journal of Neonatal-Perinatal Medicine, vol. 4, no. 1, pp. 9-13, 2011
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]