Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Al Qurashi, M.a; b; e; * | Al Qahtani, A.b; d | Al Hindi, M.a; b; e | Mustafa, A.a; b; e | Ahmed, A.a; b; e | Aga, S.S.b; c; e | Al Khotani, A.f | Kandil, H.a; b; e | Alallah, J.a; b; e | Sallam, A.a; b; e
Affiliations: [a] Department of Pediatrics, King Abdulaziz Medical City-Jeddah, Ministry of National Guard Health Affairs (MNGHA), Jeddah, Saudi Arabia | [b] College of Medicine-Jeddah, King Saud Bin Abdul Aziz University for Health Sciences (KSAU-HS), Jeddah, Saudi Arabia | [c] Department of Basic Medical Sciences, College of Medicine-Jeddah, King Saud Bin Abdul Aziz University for Health Sciences (KSAU-HS), Jeddah, Saudi Arabia | [d] Department of Educational Technology, College of Medicine-Jeddah, King Saud Bin Abdul Aziz University for Health Sciences (KSAU-HS), Jeddah, Saudi Arabia | [e] King Abdullah International Medical Research Centre (KAIMRC), Ministry of National Guard Health Affairs (MNGHA), Riyadh, Saudi Arabia | [f] Department of Pediatrics, College of Medicine, Um Al Qura University, Makkah, Saudi Arabia
Correspondence: [*] Address for correspondence: Mansour Al Qurashi, Department of Pediatrics, King Abdulaziz Medical City-Jeddah, Ministry of National Guard Health Affairs (MNGHA), Saudi Arabia. E-mail: [email protected].
Abstract: OBJECTIVE:To assess the current practice in using volume-targeted ventilation among neonatologists working at the Neonatal Intensive Care Units (NICU) of Saudi Arabia. METHODS:The questionnaire was provided electronically to 153 practicing Neonatologists working in 39 NICUs. The survey’s results were received and statistically analyzed. RESULTS:One hundred nineteen (119) responses were received with, a 78% response rate. Volume Targeted Ventilation (VTV) was used routinely by 67.2%, whereas 21.8% still use only pressure control (PC)/pressure limited (PL) mode. During the acute phase of ventilation support, Assist Control was the most popular synchronized mode, whereas Synchronized Intermittent Mandatory Ventilation (SIMV) with pressure support (PS) or PSV were the two most common modes during the weaning phase, 31.8%, and 31% respectively. The majority of the neonatologists used a tidal volume of 4 ml/kg as the lowest and 6 ml/kg as the highest. The major reasons for not implementing VTV were the limited availability of ventilator devices that have an option of VTV, followed by lack of experience. CONCLUSION:VTV is the predominant ventilation practice approach among neonatologists working in the KSA. Limited availability and lack of experience in using are the main challenges. Efforts to equip NICUs with the most advanced ventilation technology, enhance practitioners’ experience and sufficient training in its use are warranted.
Keywords: Neonate, Saudi Arabia, survey, volume targeted ventilation
DOI: 10.3233/NPM-240054
Journal: Journal of Neonatal-Perinatal Medicine, vol. 17, no. 5, pp. 653-660, 2024
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]