Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Bimpong, S.a; * | Abaidoo, C.S.b | Tetteh, J.b | Okwan, D.b
Affiliations: [a] Department of Anatomy, School of Medicine, University for Development Studies, Tamale, Ghana | [b] Department of Anatomy School of Medicine and Dentistry, Kwame Nkrumah University of Science and Technology, Kumasi, Ghana
Correspondence: [*] Address for correspondence: S. Bimpong, Department of Anatomy, School of Medicine, University for Development Studies, Tamale, Ghana. Tel.: +233 244988328; E-mail: [email protected].
Abstract: BACKGROUND:One key factor proven to increase quality of pregnancy outcome has been antenatal care (ANC) service. The perinatal triad of mother, placenta and fetus becomes functionally complete with a functional umbilical cord. The objective of the study was to establish mathematical models to predict the outcome of umbilical cord morphometric parameters using maternal first antenatal care visit biometric indices. METHOD:This analytical descriptive cross-sectional study was conducted on 240 pregnant women who attended antenatal care for the first time in their first trimester at the Victory Maternity Home and Clinic in the Kumasi Metropolis, between April 2016 and October 2019. Umbilical cord length, diameter, area, volume and weight were measured after delivery. Maternal first antenatal care visit blood pressure was taken and their non-fasting blood samples were collected and lipid profile done. RESULTS:Mean values for umbilical cord measurements were; cord length, 38.10±7.86 cm; diameter, 1.04±0.17 cm; area, 66.10±24.49 cm2 and volume was 34.02±11.16 cm3 respectively while mean cord weight was 65.01±21.35 g. The study found that a unit increase in total cholesterol led to an increase of 2.33 units in umbilical cord length, high-density lipoprotein also resulted in 0.06 units increase in cord diameter while low-density lipoprotein decreases cord length by 3.31 units. Also, a unit increase in maternal booking total cholesterol resulted in 2.33 units increase in umbilical cord length. CONCLUSION:Maternal first antenatal care visit total cholesterol, high-density lipoprotein and low-density lipoprotein could influence the outcome of umbilical cord length, diameter and area.
Keywords: Antenatal care, biometric indices, diastolic blood pressures, low-density lipoprotein, maternal, systolic blood pressures, total cholesterol and umbilical cord
DOI: 10.3233/NPM-210734
Journal: Journal of Neonatal-Perinatal Medicine, vol. 15, no. 1, pp. 129-136, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]