Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Review Article
Authors: Alhasoon, M.A.; *
Affiliations: Department of Pediatrics, Unaizah College of Medicine and Medical Sciences, Qassim University, Kingdom of Saudi Arabia
Correspondence: [*] Address for correspondence: M.A. Alhasoon, MD, Department of Pediatrics, Unaizah College of Medicine and Medical Sciences, Qassim University, Kingdom of Saudi Arabia. Tel.: +966 555179968; E-mail: [email protected].
Abstract: BACKGROUND:Being a rare condition, the incidence of chylothorax among neonates is low, but the mortality rate is high. In a dire effort to reduce the risk of death, octreotide treatment is used to effectively treat acquired and congenital chylothorax. Octreotide is proven to effectively treat chylothorax in pre-term and full-term neonates. However, previous studies have not consistently demonstrated the optimal dose of octreotide or the best mode of administration. The objectives of this work were to review previous literature to determine the outcomes of administering high doses of octreotide compared to lower dose regimens in neonates with chylothorax and to determine best practices. METHODS:A literature search was performed using electronic databases using the key words neonates, chylothorax, and octreotide. RESULTS:Octreotide has been administrated in doses ranging from 0.5μg/kg/h to > 20μg/kg/h. Both low- and high-doses of octreotide are effective in resolving chylothorax with little to no side effects. When side effects were reported, neonates experienced side effects that are less significant in nature and scope. CONCLUSIONS:We recommend that the dose of octreotide in neonatal chylothorax can be titrated safely to a maximum of 20μg/kg/h without significant side effects.
Keywords: Chylothorax, high dose, neonates, octreotide.
DOI: 10.3233/NPM-200644
Journal: Journal of Neonatal-Perinatal Medicine, vol. 14, no. 4, pp. 457-461, 2021
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]