Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Attar, M.A.a; * | Dechert, R.E.b | Donn, S.M.a
Affiliations: [a] Department of Pediatrics and Communicable Diseases, Division of Neonatal-Perinatal Medicine, Ann Arbor, Michigan, USA | [b] Department of Critical Care Support Services Michigan Medicine, University of Michigan, Ann Arbor, Michigan, USA
Correspondence: [*] Address for correspondence: Mohammad A. Attar, MD, Department of Pediatrics and Communicable Diseases, Division of Neonatal-Perinatal Medicine, Ann Arbor, Michigan, USA. Tel.: +1 734 763 4109; Fax: +1 734 763 2278; E-mail: [email protected].
Abstract: INTRODUCTION:High frequency jet (HFJV) and oscillatory (HFOV) ventilation were used to rescue newborns with congenital diaphragmatic hernia (CDH), who failed conventional mechanical ventilation (CV). Changes in ventilator settings and pulmonary gas exchange were evaluated following transition to high frequency ventilation (HFV). METHODS:Records of patients with CDH rescued with HFV prior to surgical intervention between 2006 and 2015 were reviewed. Mean airway pressure (Pāw) and arterial blood gases during CV and those obtained within the first hour of HFV were compared. A composite repeated measure analysis was performed to evaluate longitudinal and intergroup variances. RESULTS:Twenty-seven patients were rescued from CV, 16 by HFJV and 11 by HFOV. The two groups had similar gestational ages and birth weights. Prior to HFV, both groups had similar Pāw, PaCO2, FiO2 and PaO2. HFV was associated with a significant improvement in ventilation, and the rate of decrease of PaCO2 was no different between groups. There was a significantly higher increase in Pāw increase with HFOV compared to HFJV. CONCLUSIONS:In newborns with CDH rescued with HFV, ventilation improved but Pāw was significantly lower in patients supported with HFJV compared to HFOV.
Keywords: Hemodynamic, rescue, respiratory failure, surgery, neonates
DOI: 10.3233/NPM-1813
Journal: Journal of Neonatal-Perinatal Medicine, vol. 12, no. 2, pp. 173-178, 2019
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]