Article type: Research Article
Authors: Reich, J.D.a; * | Haight, D.b | Reich, Z.S.a
Affiliations: [a] The Watson Clinic LLP, Lakeland, FL, USA | [b] University of South Florida, Morsani College of Medicine, Department of Internal Medicine, Division of Infectious Disease and International Medicine, Tampa, FL, USA
Correspondence: [*] Address for correspondence: Jonathan D. Reich, MD, The Watson Clinic LLP, 1600 Lakeland Hills Blvd., Lakeland, FL 33813, USA. Tel.: +1 863 660 7188; E-mail: [email protected].
Abstract: OBJECTIVE: To evaluate the incidence of otherwise undiagnosed congenital heart disease (CHD) in a population of children born in a hospital with routine pulse oximetry (RPO) screening compared to children born at home. METHODS: We reviewed 15 years of births at 2 hospitals for incidence of undiagnosed CHD with RPO. The Health Department reviewed the same data for out of hospital births. RESULTS: A total of 50,545 hospital births were screened and 1,274 children were born outside the hospital. There were 28 hospital-born babies diagnosed with cyanotic CHD prior to nursery discharge. Only one of these babies would not have been diagnosed without RPO. Three children were missed and there were 3 false positives. Sensitivity and positive predictive value of RPO was 25%, specificity and negative predictive value of RPO exceed 99%. The incidence of CHD requiring RPO diagnosis was roughly one birth per 50,000. Two children born at home with undiagnosed CHD were missed. One of these children presented with neonatal demise. CONCLUSION: RPO screening is still valuable in diagnosing CHD only diagnosable with RPO. However, the incidence of CHD requiring RPO to diagnose is similar to other congenital diseases which are not mandated national screening tests. In our limited experience a patient is roughly 25 times more likely to have undiagnosed CHD if they are born outside of a hospital.
DOI: 10.3233/NPM-1651
Journal: Journal of Neonatal-Perinatal Medicine, vol. 10, no. 1, pp. 71-77, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]