Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Alonzo, Corrie J.; * | Fairchild, Karen D.
Affiliations: University of Virginia, Charlottesville, VA, USA
Correspondence: [*] Address for correspondence: Corrie J. Alonzo, Department of Pediatrics Box 800386, University of Virginia Health System, Hospital Drive, Charlottesville, VA 22908, USA. Tel.: +1 970 580 3640; Fax: +1 434 243 0649; E-mail: [email protected].
Abstract: BACKGROUND:Dexamethasone is administered to some preterm infants with chronic lung disease to facilitate weaning from mechanical ventilation. Heart rate characteristics (HRC), including heart rate variability (HRV), may be impacted by glucocorticoids and may predict extubation readiness. A commercially available monitor developed for sepsis detection continuously calculates HRV and an HRC index, which are inversely related. OBJECTIVES:Determine the impact of dexamethasone on HRV and the HRC index, in relation to extubation success. METHODS:We identified 109 preterm infants who received dexamethasone while on mechanical ventilation and had HRC index monitoring data available. Average hourly HRV and HRC index were compared the day before and the day after initiation of dexamethasone in three groups: infants who remained on mechanical ventilation, those who were successfully extubated, and those who were extubated and required reintubation in < 3 days. RESULTS:There was a significant increase in HRV and decrease in the HRC index the day after dexamethasone was started (HRV 16.2±0.5 vs 27.6±1.1 ms; HRC index 1.51±0.11 vs. 0.79±0.06 mean SE, p < 0.001). The 63 infants who were extubated within a day of starting dexamethasone had significantly higher HRV compared to those who remained on mechanical ventilation. There was no difference in HRV or its change with dexamethasone in the 45 infants who remained successfully extubated compared to the 18 infants who required reintubation within 3 days. CONCLUSION:Dexamethasone improves HRV and lowers the HRC index in preterm infants with chronic lung disease on mechanical ventilation.
Keywords: Dexamethasone, steroids, glucocorticoids, heart rate variability, premature infant, mechanical ventilation, chronic lung disease
DOI: 10.3233/NPM-16157
Journal: Journal of Neonatal-Perinatal Medicine, vol. 10, no. 4, pp. 425-430, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]