Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Sukanya, A.; * | Rajeswari, R.
Affiliations: Department of Computer Applications, Bharathiar University, Coimbatore, India
Correspondence: [*] Corresponding author. A. Sukanya, Department of computer applications, Bharathiar University, Coimbatore, India. E-mail: [email protected].
Abstract: This paper describes a method to extract the cardiac vessels in coronary angiography images. The cardiac vessel extraction technique is a significant process in clinical scenario for cardiac image analysis of Coronary Computed Tomography Angiography (CCTA) datasets. CCTA is a speedy growing non-invasive cardiac imaging modality that provides vital diagnostic information for the cardiac disease diagnosis. Since cardiac vessel extraction for CTA images is a prime issue in computer-aided medical diagnosis, algorithms or systems for vessel detection are always demanded. In order to support computer-aided diagnosis, a modified Frangi’s vesselness measure based on gradient and grayscale measure of the cardiac images is proposed in this work. The experimental result shows that the proposed method can effectively enhance vascular structures and suppress the pseudo vascular structures. It eliminates the background noise and helps in separation of neighboring vessels. The proposed vesselness measure were statistically analyzed by analysis of variance (i.e) one-way ANOVA. The statistical analysis also proves that the proposed vesselness measure based on gradient and grayness values extracts the vessel segments more effectively from the background. Hence the method detects the cardiac vessels more effectively by incorporating the fact that the gradient and grayscale values are comparatively different inside and outside the cardiac vessels. The proposed method has been evaluated on 3D CCTA images and the results are promising.
Keywords: Computed Tomography Angiography (CTA), coronary artery, vesselness measure
DOI: 10.3233/JIFS-182613
Journal: Journal of Intelligent & Fuzzy Systems, vol. 37, no. 2, pp. 2327-2336, 2019
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]