Affiliations: Department of Environmental Science, Zhejiang
University, Hangzhou 310028, China. E-mail: [email protected]
Note: [] Corresponding author
Abstract: Nine PAHs were surveyed in communication air of Hangzhou. The
results indicated that the PAHs pollution is very serious and the total sum of
9 PAHs, on the average are 3.39- 13.82 µg/m3. The PAHs signatures for all
streets are similar to each other. Multivariate statistical techniques were
used to investigate source apportionment for PAHs. A factor analysis/multiple
regression model was successfully applied to the study. The most important
three PAHs sources in communication air are diesel emission, gasoline engine
emission, coal-burning accounting for 61. 1 ± 6.4%, 19.9 ± 8.3%,
10.8 ± 10.8% of total PAHs, respectively. The relationship for three
source tracers and total PAHsis: [PAHs] =1.471(± 0.155)[Phen] + 2.538
(± 2.522)[1-Mepy] + 2.254 (± 0.943)[Chry] + 1.022 (±
1.767).
Keywords: PAHs, air, source apportionment, city communication