Article type: Research Article
Authors: Zhao, Yilina | Jiang, Xiaoyanb; * | Li, Xiaobingc | Gao, Pand | Shao, Yanglue
Affiliations: [a] School of Water Conservancy and Civil Engineering, Xizang Agriculture and Animal Husbandry College, Nyingchi, Xizang, China | [b] School of Electrical Engineering, Xizang Agriculture and Animal Husbandry College, Nyingchi, Xizang, China | [c] Shannan Power Supply Company, State Grid Tibet Power Co., Ltd., Xizang, China | [d] Tibet Shannan Naidong Xiehe Solar Power Generation Co., Ltd., Xizang, China | [e] Concord New Energy Group Limited, Beijing, China
Correspondence: [*] Corresponding author: Xiaoyan Jiang, School of Electrical Engineering, Xizang Agriculture and Animal Husbandry College, Nyingchi, Xizang 860000, China. E-mail: [email protected].
Abstract: Centralized photovoltaic power station is an important part of building a new power system, whose power generation unit is the main equipment of the photovoltaic power station. Therefore, it is the basis of analyzing the harmonic characteristics of photovoltaic power generation to study the harmonic generation mechanism and influencing factors of power generation units and establish the harmonic equivalent model of photovoltaic power generation units. In this paper, firstly, the harmonic generation mechanism is analyzed from the aspects of sinusoidal pulse width modulation (SPWM) and dead time of inverter. Secondly, the correlation analysis of influencing factors of output power of photovoltaic power generation unit is carried out, and then the influence of output power on harmonics is analyzed. Thirdly, the harmonic characteristic model of photovoltaic power generation unit based on actual photovoltaic power station and influencing factors is constructed. Finally, the theoretical simulation of SPWM modulation and dead time is verified and analyzed, and the simulation results of harmonic characteristics are compared with the measured data. The results show that the harmonic characteristic of the centralized photovoltaic power station is mainly to generate high-frequency odd-order harmonics, which will generate extra high-frequency even-order harmonics when the irradiation is too high or too low, and cause interharmonics when the irradiance fluctuates on the DC side of the inverter.
Keywords: Photovoltaic power generation, correlation analysis, SPWM, dead time, harmonic characteristic
DOI: 10.3233/JCM226035
Journal: Journal of Computational Methods in Sciences and Engineering, vol. 22, no. 4, pp. 1235-1250, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]