Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Li, Guana | Wang, Biaob | Bu, Xianglic; * | Wang, Dib | He, Jingkanga
Affiliations: [a] Electronic and Information Engineering, North China Institute of Science and Technology, Beijing, China | [b] Safety Engineering, North China Institute of Science and Technology, Beijing, China | [c] Mechanical and Electrical Engineering, North China Institute of Science and Technology, Beijing, China
Correspondence: [*] Corresponding author: Xiangli Bu, Mechanical and Electrical Engineering, North China Institute of Science and Technology, Beijing, China. E-mail: [email protected].
Abstract: This paper proposes a spray control system with variable particle size to address the inaccuracy of droplet size control in the existing spray dedusting system. A PID control algorithm with stable air and water pressure is adopted to ensure droplet size uniformity. An experimental device of the droplet control system is built in the laboratory to verify the algorithm’s effectiveness. Experiments were conducted using PLC as the core controller to verify the influence of different types of nozzles on the droplet size under the same air pressure and water pressure through experiments. The results show: (1) the systems droplet size range is 8–200 μm, which meets the dust removal conditions of respirable dust and is suitable for dust removal. (2) When measured under identical experimental conditions, the droplet size decreases as the nozzle angle increases. It was shown that the spray system combined with various sprinklers can achieve full droplet size coverage and improve the efficiency of dust-fall. It provides a solution for the existing dust removal system to flexibly change the droplet size according to the dust size.
Keywords: Spray dedusting, droplet size control, PID control
DOI: 10.3233/JCM-215857
Journal: Journal of Computational Methods in Sciences and Engineering, vol. 22, no. 2, pp. 623-634, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]