Article type: Research Article
Authors: Schubert, Carla R.a; * | Paulsen, Adam J.a | Pinto, A. Alexa | Merten, Nataschab | Cruickshanks, Karen J.a; b
Affiliations: [a] Department of Ophthalmology and Visual Sciences, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, WI, USA | [b] Department of Population Health Sciences, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, WI, USA
Correspondence: [*] Correspondence to: Carla R. Schubert, MS, Department of Ophthalmology and Visual Sciences, 610 Walnut Street, Rm 1087 WARF, Madison, WI 53726, USA. Tel.: +1 608 265 3722; E-mail: [email protected].
Abstract: Background: Stored blood samples from longitudinal cohort studies may be useful for studying biomarkers of preclinical Alzheimer’s disease. Objective: This study aimed to determine the reliability of amyloid-β40 and amyloid-β42 (Aβ40, Aβ42), total tau (TTau), and neurofilament light (NfL) concentrations measured in blood samples stored long-term at -80°C. Methods: Aβ40, Aβ42, TTau, and NfL were measured in serum and plasma samples from two longitudinal cohort studies. Serum samples had been stored at -80°C for 5 (n = 24), 14 (n = 24), and 20 years (N = 78) and plasma samples had been stored for 16 years (N = 78). Biomarker concentrations were measured in duplicate using a single molecule array assay (Simoa; Quanterix, Billerica, MA). Replicate samples for each sample type and storage length were included. Results: The concentrations of Aβ40, Aβ42, TTau, and NfL were within expected ranges. Some serum TTau concentrations were below the limit of detection. The average intra-assay coefficients of variation (CV) for duplicate measures were 2–7% for all assays except for serum TTau, which were higher (CVs 13% and 17%). Mean differences in original replicate pair Aβ40, Aβ42, and NfL concentrations were slightly greater in samples stored for longer versus shorter time periods. Conclusion: Aβ40, Aβ42, TTau, and NfL can be measured in serum and plasma samples that have been stored up to 20 years at -80°C. Long-term storage may be associated with small increases in the variability of concentrations in samples stored 14 or more years.
Keywords: Alzheimer’s disease, amyloid-β, blood biomarkers, epidemiology, neurofilament light, plasma, serum, single molecule array, total tau
DOI: 10.3233/JAD-215096
Journal: Journal of Alzheimer's Disease, vol. 85, no. 3, pp. 1021-1029, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]