Article type: Research Article
Authors: Rector, Michael* | Intziegianni, Konstantina | Müller, Steffen | Mayer, Frank | Cassel, Michael
Affiliations: University Outpatient Clinic, Sports Medicine and Sports Orthopedics, Universität Potsdam, Potsdam, Germany
Correspondence: [*] Corresponding author: Michael Rector, University Outpatient Clinic, Sports Medicine and Sports Orthopedics, Universität Potsdam, Am Neuen Palais 10, Haus 12, 14469 Potsdam, Germany. Tel.: +49 0331/977 1768; Fax: +49 0331/977 1296; E-mail:[email protected]
Abstract: BACKGROUND: The Achilles tendon (AT) requires optimal material and mechanical properties to function properly. Calculation of these properties depends on accurate measurement of input parameters (i.e. tendon elongation). However, the measurement of AT elongation with ultrasound during maximum voluntary isometric contraction (MVIC) is overestimated by ankle joint rotation (AJR). Methods to correct the influence of this rotation on AT elongation exist, yet their reproducibility in clinical settings is unknown. OBJECTIVE: To evaluate the test-retest reproducibility of AT elongation during MVIC after AJR correction. METHODS: Ten participants attended test and retest measurements where they performed plantar-flexion MVIC on a dynamometer. Simultaneously, ultrasound recorded AT elongation as the displacement of the medial gastrocnemius-myotendinous junction, while an electrogoniometer measured AJR. The ankle was then passively rotated to the AJR achieved during MVIC and AT elongation again determined. Elongation was corrected by subtracting this passive AT elongation from the total AT elongation during MVIC. Reproducibility was evaluated using ICC (2.1), test-retest variability (TRV, %), Bland-Altman analyses (Bias ± LoA [1.96*SD]) and standard error of the measurement (SEM). RESULTS: Corrected AT elongation reproducibility exhibited an ICC = 0.79, SEM = 0.2 cm and TRV = 20 ± 19%. Bias ± LoA were determined to be 0.0 ± 0.8 cm. CONCLUSIONS: Using this ultrasound and electrogoniometer-based method, corrected AT elongation can be assessed reproducibly.
Keywords: Ultrasonography, %Achilles tendon, %reproducibility, %isokinetic, %ankle joint rotation
DOI: 10.3233/IES-160644
Journal: Isokinetics and Exercise Science, vol. 25, no. 1, pp. 47-52, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]