Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Northgraves, Matthew J.a; b; * | Hayes, Stephen C.a | Marshall, Philipa | Madden, Leigh A.c | Vince, Rebecca V.a
Affiliations: [a] Department of Sport, Health and Exercise Science, University of Hull, Hull, UK | [b] Department of Health Sciences, University of York, York, UK | [c] School of Biological, Biomedical and Environmental Sciences, University of Hull, Hull, UK
Correspondence: [*] Corresponding author: Matthew J. Northgraves, Department of Sport, Health and Exercise Science, University of Hull, Hull, HU6 7RX, UK. Tel.: +44 1904 321614; E-mail:[email protected]
Abstract: BACKGROUND: Simple field tests are often used to assess functional mobility in clinical settings. Despite having many benefits, these tests are susceptible to measurement error and individual variation. OBJECTIVES: To examine the test-retest and absolute reliability of timed up and go test (TUG), five times sit-to-stand (FTSTS), stair climb test (SCT) and 6 minute walk (6MWT). METHODS: Over two sessions, thirty-five subjects (30-74 years), repeated the five tests approximately four weeks apart. Test-retest reliability (intraclass correlations [ICC]) and absolute reliability (95% limit of agreements [95% LOA]; standard error of measurement [SEM] and minimum detectable change [MDC]) were calculated. RESULTS: All five tests had high test-retest reliability (ICC > 0.95) although significant between session changes were present for the TUG and FTSTS (p < 0.05). FTSTS displayed the greatest measurement error whilst 95% LOA was the most conservative measure of absolute reliability. CONCLUSIONS: The results of this study indicate that the TUG, FTSTS, SCT and 6MWT are reliable when performed four weeks apart. Furthermore, the inclusion of SEM, MDC and 95% LOA provides reference values to aid in identifying changes over time above those of measurement error and individual variation.
Keywords: TUG, FTSTS, stair climb, 6MWT
DOI: 10.3233/IES-160614
Journal: Isokinetics and Exercise Science, vol. 24, no. 3, pp. 171-179, 2016
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]