Authors: Nugent, Erin P.a; * | Snodgrass, Suzanne J.a | Callister, Robinb
Affiliations: [a] Discipline of Physiotherapy, School of Health Sciences, The University of Newcastle, NSW, Australia | [b] Priority Research Centre for Physical Activity and Nutrition, The University of Newcastle, NSW, Australia
Correspondence: [*] Corresponding author: Erin Nugent, School of Health Sciences, Hunter Building, The University of Newcastle, Callaghan, NSW 2308, Australia. Tel.: +61 2 4921 2089; Fax: +61 2 4921 7053; E-mail:[email protected]
Abstract: BACKGROUND: The reproducibility of the HUMAC-NORM isokinetic dynamometer has not yet been established for the muscles around the knee. Previous research suggests practice-based improvement (PBI) may impact upon the reproducibility of isokinetic testing. OBJECTIVE: To investigate test-retest reproducibility of knee flexion and extension isokinetic findings at different velocities, including the influence of familiarisation. METHODS: Seventy physically active, healthy participants with no experience in isokinetic dynamometry performed five repetitions of continuous concentric knee flexion and extension at 60, 120, 180 and 240°/s on four occasions. Peak moment, angle of peak moment, total work and average power were recorded. Reproducibility was determined using percentage change in the mean, typical error and intraclass correlation coefficients (ICC). RESULTS: For knee flexion and extension, group data met desirable reproducibility criteria for most outcomes and velocities after Trial 2. Within-subject reproducibility generally met acceptable reliabilty criteria after Trial 2 for knee extension, but was predominantly unacceptable for knee flexion. ICC's were acceptable from Trial 2, except for angle of peak moment which did not achieve an acceptable level of reliabilty across any trials, outcomes or velocities. CONCLUSIONS: The HUMAC-NORM demonstrates excellent reproducibility for peak moment, average power and total work parameters for the major knee muscles after one trial. One familiarisation session is recommended prior to testing to minimise the impact of PBI. Additional familiarisation is beneficial when testing individuals, higher velocities and knee flexion.
Keywords: Reproducibility of results, muscle strength dynamometer, practice-based improvement, knee
DOI: 10.3233/IES-150582
Journal: Isokinetics and Exercise Science, vol. 23, no. 3, pp. 205-214, 2015
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]