Article type: Research Article
Authors: Strauss, G.R.a; * | Allen, C.a | Munt, M.a | Zanoli, J.a
Affiliations: [a] School of Physiotherapy, Curtin University of Technology, Selby Street, Shenton Park, WA, 6001, Australia
Note: [*] Corresponding author, Tel.: +61 9 3513652; Fax: +61 9 3513636; E-mail: [email protected].
Abstract: The aim of this study was to investigate the torque produced using two commonly employed approaches to isokinetic strength testing, the continuous and discrete testing approaches, using the same dynamometer. The continuous testing approach consisted of four repetitions of maximal reciprocal concentric (Con) and eccentric (Ecc) muscle actions, with a 4-min pause after each set of repetitions to allow recovery. The discrete testing approach consisted of four maximal Con and Ecc muscle actions, each action separated by a 30-s pause. A 2-min pause followed each velocity. Both approaches were performed at velocities of 60, 120 and 180° s−1. Each testing approach therefore encompassed the same number of maximal repetitions and the same pause time, giving equal total work and total recovery times. Full range average torque (FRAT), truncated range average torque (TRAT) and peak torque (PT) were derived from all generated torque curves. The best data (highest torque values) were utilised in subsequent analyses. Each dependent variable (FRAT, TRAT and PT) was separately analysed using a three-way ANOVA with repeated measures on all three factors: testing approach (continuous and discrete), velocity (60, 120 and 180° s−1and muscle action (Con and Ecc). A significant interaction between the independent variables testing approach and muscle action existed for all measures of strength. Contrasts revealed no difference between the Con muscle actions of the continuous and discrete testing approaches, however, the torques produced in Ecc muscle actions with the discrete testing approach were significantly greater than those produced in the continuous testing approach. Ecc torques and any derived measures incorporating Ecc torques are therefore not comparable between the testing approaches.
Keywords: Continuous and discrete testing, Concentric torque, Knee extensors
DOI: 10.3233/IES-1996-53-406
Journal: Isokinetics and Exercise Science, vol. 5, no. 3-4, pp. 135-141, 1996
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]