Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Joyce, Christopher J.a; * | Bernier, Julie N.a; ** | Perrin, David H.a; ***; ****
Affiliations: [a] University of Virginia, Charlottesville
Note: [*] Doctoral Student, University of Virginia, Charlottesville.
Note: [**] Doctoral Student in Sports Medicine, University of Virginia, Charlottesville.
Note: [***] Associate Professor and Director of Graduate Athletic Training Education and Research, University of Virginia, Charlottesville.
Note: [****] Address reprint requests to David H. Perrin, Memorial Gymnasium, University of Virginia, Charlottesville, VA 22903.
Abstract: The purpose of this study was to determine whether external compression would cause a decrease in the isokinetic muscular endurance of the quadriceps and hamstring muscle groups. Subjects were tested on the Cybex II dynamometer (Cybex, Ronkonkoma, NY) under two conditions: with external compression applied to the thigh and without external compression applied to the thigh. External compression was applied with a lower extremity blood pressure cuff inflated to a predetermined clinically standardized pressure. The subjects performed an isokinetic endurance test consisting of 30 maximal repetitions at 180 deg/sec under both conditions. A paired t test showed no statistical differences (p > 0.05) between the mean total work, work over the first five repetitions, and work over the last five repetitions between the two conditions for the quadriceps and the hamstring muscle groups. Results indicated that external compression applied to the thigh at 30 mm Hg caused no significant decrease in the isokinetic muscular endurance of the quadriceps or hamstrings. Further research is indicated to determine whether external compression could influence other aspects of muscular performance.
Keywords: External compression, Isokinetic endurance, work
DOI: 10.3233/IES-1994-4206
Journal: Isokinetics and Exercise Science, vol. 4, no. 2, pp. 81-84, 1994
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]