Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: McLean, Karen Palmer*; ** | Conner, Sandra***
Note: [*] Assistant Professor of Physical Therapy, University of Wisconsin, LaCrosse, WI. (Graduate Associate and doctoral student at Arizona State University when these data were collected).
Note: [**] Address reprint requests to Karen Palmer McLean, Room 243 Cowley Hall, University of Wisconsin, LaCrosse, WI 54601.
Note: [***] Physical therapist, St. Joseph's Center of Sports Medicine, Phoenix, AZ.
Abstract: The reliability of the trunk Biodex unit (Shirley, NY) was assessed in asymptomatic men (n = 30) and women (n = 29) 20 to 35 years of age. Flexion peak torque (FPT) and extension peak torque (EPT) and maximal repetition work (MRW) were evaluated at 60, 120, and 150 deg/sec. Variables were measured on two occasions on each of 3 days. Data were analyzed using analysis of variance with repeated measures (p < 0.01). Reliability was estimated by intraclass correlation coefficients. For men, EPT at 60 deg/sec on day 1 was significantly lower than on days 2 and 3. For women, values on day 1 were significantly lower than on days 2 and 3 for all parameters measured except EPT at 60 deg/sec, FPT at 60 and 150 deg/sec, and FMRW at 60 and 120 deg/sec. The occasion effect was nonsignificant for women. For men, values for FPT at 60 and 120 deg/sec were significantly lower on occasion 2, suggesting a fatigue effect. Reliability coefficients ranged from 0.81 to 0.98 for men and women, with the exception of EMRW at 150 deg/sec for men (R = 0.54) and 60 deg/sec for women (R = 0.57). Reliable Biodex trunk strength values can be obtained using 1 day of testing for men, except for EPT at 60 deg/sec, which requires 1 day of practice. Women require 1 day of practice for most of the parameters tested. It is not necessary to test men or women twice on the same day. Reliable EMRW at 150 deg/sec for men and 60 deg/sec for women was not achieved.
Keywords: Isokinetic testing, trunk strength, low-back pain, Biodex, peak torque, maximal repetition work
DOI: 10.3233/IES-1994-4105
Journal: Isokinetics and Exercise Science, vol. 4, no. 1, pp. 20-29, 1994
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]