Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Kramer, Johna; *; ** | Agnidis, Zoea; *** | Bourne, Roberta; **** | Rorabeck, Cecila; *****
Affiliations: [a] University of Western Ontario
Note: [*] Department of Physical Therapy, Faculty of Applied Health Sciences, University of Western Ontario, London, Ontario, Canada.
Note: [**] Address reprint requests to Dr. John F. Kramer, Department of Physical Therapy, Faculty of Applied Health Sciences, University of Western Ontario, London, Ontario, Canada N6G 1H1.
Note: [***] Department of Physical Therapy, Faculty of Applied Health Sciences, University of Western Ontario, London, Ontario, Canada.
Note: [****] Division of Surgery, University Hospital, London, Ontario, Canada.
Note: [*****] Division of Surgery, University Hospital, London, Ontario, Canada.
Abstract: The purpose of this study was to determine test–retest reliability of knee extensor and flexor strength measurements in elderly patients after total knee replacement. Twenty men and 16 women (mean age 70 ± 4 years; mean postsurgical time 19 ± 11 months) were tested isometrically at 45 deg flexion with a hand-held dynamometer and isokinetically at 60 deg/sec angular velocity using a Kin-Com dynamometer during two test sessions within a 2-week period. All patients were independent in activities of daily living, ambulation, and stair activities, and none had previous experience with equipment-based isometric or isokinetic tests. Isometric torques at 45 deg flexion and isokinetic peak torques were reliable (intraclass correlation coefficients > 0.75) on a single test session, whereas averaging torques over two test sessions was required to produce reliable torques at 45 deg flexion during isokinetic movements. Reliability was greater during isometric than during isokinetic tests, greater during knee extension than during knee flexion, and, during the isokinetic tests, greater for peak torques than for torques at 45 deg flexion. Future studies should examine (1) reliability during the second and third test sessions when using the present and other tests protocols, and (2) means of familiarizing the patient with the test procedures in an effort to improve reliability.
Keywords: Total knee replacement, reliability, extensor/flexor strength
DOI: 10.3233/IES-1992-2207
Journal: Isokinetics and Exercise Science, vol. 2, no. 2, pp. 76-81, 1992
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]