Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Greenfield, Bruce H.a; *; ** | Catlin, Pamela A.a; *** | George, Todd W.a; **** | Hastings, Beverlee J.a; **** | Mees, Karen A.a; ****; *****
Affiliations: [a] Emory University
Note: [*] Clinical Instructor, Division of Physical Therapy, Department of Rehabilitation Medicine, Emory University School of Medicine, Atlanta, GA. Mr. Greenfield is also affiliated with Physical Therapy Associates of Metro Atlanta.
Note: [**] Address reprint requests to Bruce H. Greenfield, Physical Therapy Associates of Metro Atlanta, 6909 Tara Blvd., Jonesboro, GA 30236.
Note: [***] Associate Professor and Director, Division of Physical Therapy, Department of Rehabilitation Medicine, Emory University School of Medicine, Atlanta, GA.
Note: [****] At the time of the study, Mr. George, Ms. Hastings, and Ms. Mees were students in the Division of Physical Therapy, Department of Rehabilitation Medicine, Emory University School of Medicine, Atlanta, GA. The study was completed as a requirement for the Master of Physical Therapy degree.
Note: [*****] Associate Professor and Director, Division of Physical Therapy, Department of Rehabilitation Medicine, Emory University School of Medicine, Atlanta, GA.
Abstract: This study investigated intratester, intertester, and intrasubject reliability, within and between two test sessions, of reciprocal contractions of the quadriceps and hamstrings at 90°/sec and 200°/sec in healthy individuals. The MERAC (Muscular Evaluation Rehabilitation and Conditioning, Universal Corporation, Cedar Rapids, IA) was used to test the dominant lower extremity of 33 healthy subjects who attended two test sessions scheduled two weeks apart. For each observation, the subject performed four submaximal and three maximal warm-up reciprocal contractions prior to three maximal test contractions of reciprocal, knee flexion, and extension at each speed. Three observations occurred per test session, one by one examiner and two by a second examiner. The order of examiners and speeds was random. The variables of peak torque, average work, and average power were measured. All correlation coefficients for intratester and intertester reliability were statistically significant (p < 0.05). Further research is indicated to determine isokinetic testing protocols that optimize stability of performance.
Keywords: Reliability, reciprocal contractions, isokinetic testing
DOI: 10.3233/IES-1991-1406
Journal: Isokinetics and Exercise Science, vol. 1, no. 4, pp. 207-215, 1991
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]