Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Bampouras, Theodoros M.a | Relph, Nicola S.a | Orme, Duncana | Esformes, Joseph I.b
Affiliations: [a] Sport and Physical Activity, Faculty of Health and Wellbeing, University of Cumbria, Lancaster, UK | [b] Cardiff Metropolitan University, Cardiff School of Sport, Cardiff, UK
Note: [] Corresponding author: Theodoros M. Bampouras, Sport and Physical Activity, Faculty of Health and Wellbeing, University of Cumbria, Bowerham Road, Lancaster, LA1 3JD, UK. Tel.: +44 0 1524 526 531; Fax: +44 0 1524 526 527; E-mail: [email protected]
Abstract: BACKGROUND: Portable and cost-effective accelerometers can yield instantaneous results of force, power, and velocity, with minimum set-up time to assess muscle power. However, such devices must also produce both valid and reliable data. OBJECTIVE: The current study assessed the validity and reliability of the Myotest Pro wireless accelerometer (ACC). METHODS: Thirty physically active males performed two squat jump, on two separate sessions. The jump was recorded simultaneously by a force platform and ACC, which was attached to a barbell resting on the subjects' shoulders. Validity was determined using Pearson correlation coefficient (r) and t-test between the maximum force platform (F_{FP}) and ACC (F_{ACC}) force. Between session reliability of F_{ACC}, power (P_{ACC}) and velocity (V_{ACC}) from the ACC were assessed with t-test, intraclass correlation coefficient (ICC), and coefficient of variation (CV). RESULTS: F_{ACC} correlated highly to F_{FP} (r=0.815, p< 0.05), but there was a proportionate ratio bias of 0.81. There was no difference between sessions (p> 0.05) for any variable. High ICCs were found for all variables (F_{ACC} 0.90; P_{ACC} 0.80; V_{ACC} 0.84). Low CV was found for F_{ACC} (2.1%), P_{ACC} (3.3%) and V_{ACC} (3.2%). CONCLUSIONS: ACC is a valid and reliable tool to use for assessing barbell movement, but caution in power data interpretation is needed.
Keywords: Field measurement, muscle performance, power assessment, power production, test-retest design
DOI: 10.3233/IES-130484
Journal: Isokinetics and Exercise Science, vol. 21, no. 2, pp. 101-105, 2013
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]