Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: van Cingel, Roberta | van Melick, Nickya | van Doren, Liekea | Aufdemkampe, Geertb
Affiliations: [a] Sports Medical Center Papendal, Arnhem, The Netherlands | [b] Research Group Lifestyle and Health University of Applied Sciences, Utrecht, The Netherlands
Note: [] Address for correspondence: Robert van Cingel, Sport Medical Center Papendal, Papendallaan 7, 6816 VD Arnhem, The Netherlands. Tel.: +31 26 4834440; Fax: +31 26 4834439; E-mail: [email protected]
Abstract: The isokinetic strength of ankle inversion-eversion was twice tested, over a period of one week, by the same examiner in apparently healthy 15 women and 15 men at 30 and 120°/s. Test – retest measurements were examined for 1 and 3 sets of three repetitions. Intraclass correlation coefficients for the highest peak torque out of 1 set of 3 repetitions varied from 0.47–0.82 for men and 0.70–0.94 for women. The ICC for the mean-based PT (the 3 highest PTs out of 3 sets of 3 replicates) ranged 0.74–0.83 for men and 0.80–0.97 for women. Bland-Altman plots have indicated a largely homoscedastic distribution of the test-retest parameters. The standard error of measurement (SEM) varied from 3.6–7.00 Nm for men and 3.3–4.7 Nm for women (highest PT-based) and 2.9–5.7 Nm for men and 1.6–4.0 Nm for women (mean PT-based). Irrespective of either paradigm, there was much dispersion in the ICCs for both genders in other isokinetic parameters such as the time to PT and angle at PT. It is therefore concluded that the only reproducible isokinetic parameter under this test protocol is the peak torque.
Keywords: Isokinetics, ankle, reproducibility of results
DOI: 10.3233/IES-2009-0351
Journal: Isokinetics and Exercise Science, vol. 17, no. 3, pp. 181-188, 2009
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]