Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Çetin, Nuria | Dilek, Aysea | Aytar, Aydana | Akman, Mahmut Nafiza
Affiliations: [a] Department of Physical Medicine and Rehabilitation, Başkent University, Ankara, Turkey | [b] Department of Physical Therapy and Rehabilitation, Baskent University, Ankara, Turkey
Note: [] Address for correspondence: Nuri Çetin, Bahçelievler 5.sok No: 48, 06490, Çankaya, Ankara, Turkey. Tel.: +90 312 2126650; Fax: +90 312 2157840; E-mail: [email protected]
Abstract: We aimed to determine the test-retest reproducibility of isokinetic dynamometric measurement of the resistance to passive motion for quantitative evaluation of wrist flexor spasticity in stroke patients. In a repeated measures design, 2 raters tested each subject 3 times on 6 separate days. Twenty one sub-acute/chronic stroke patients 55 ± 14.1 years of age with an average disease duration of 7.04 ± 2.87 months volunteered to take part along with 20 age-matched healthy controls. Clinical assessment of spasticity was performed using an Ashworth Scale. Resistance measurements of 5 consecutive flexion/extension movements of the wrists were performed at 3 reselected angular velocities (10°/s, 30°/s, 45°/s), using a computerized dynamometer, set in the continuous passive joint motion mode. The maximum peak torque values in for each subject were calculated for each set of repetitions. The reproducibility of strength measurements were evaluated using single-measure and average-measure intra class correlation coefficients (ICCs). There was a significant positive correlation between Ashworth Scale and torque values. Torque values were significantly higher in groups with patients who had strokes than in the control group. The dynamometric scores were positively correlated with Ashworth Scale grades. The ICCs for intra-tester measurements were high and ranged 0.82–0.87. The Bland-Altman plots indicated no systematic bias. The standard error of measurement (SEM) ranged 0.27–0.38 Nm while the smallest real difference (SRD) ranged −1.0 Nm to 1.1 Nm). These values correspond to a mean SEM% of 31% and SRD% of 85%. These values indicate relatively large measurement error and thus does not support the use of isokinetic dynamometry, using this protocol and measurement system, in assessing wrist muscles spasticity in stroke patients.
Keywords: Spasticity, isokinetic dynamometry, reproducibility, stroke
DOI: 10.3233/IES-2008-0297
Journal: Isokinetics and Exercise Science, vol. 16, no. 1, pp. 61-67, 2008
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]