Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Optimization for Engineering, Science and Technology
Guest editors: Pandian Vasant and Junzo Watada
Article type: Research Article
Authors: Jagatheesan, K.a; * | Anand, B.b | Dey, Nilanjanc | Omar, M.d | Balas, Valentina E.e
Affiliations: [a] Department of Electrical and Electronics Engineering, Mahendra Institute of Engineering and Technology, Namakkal, TN, India | [b] Department of Electrical and Electronics Engineering, Hindusthan College of Engineering and Technology, Coimbatore, TN, India | [c] Department of Information Technology, Techno India College of Technology, Kolkata, India | [d] Faculty of Engineering at Shoubra, Benha University, Benha, Egypt | [e] Faculty of Engineering, Aurel Vlaicu University of Arad, Arad, Romania
Correspondence: [*] Corresponding author: K. Jagatheesan, Department of Electrical and Electronics Engineering, Mahendra Institute of Engineering and Technology, Namakkal, TN, India. E-mail:[email protected]
Abstract: Automated industries require high quality of power supply for better performance. Therefore, power generating units play crucial role. In this work, multi-area power system incorporates six area thermal power systems with different steam configuration is investigated with Automatic Generation Control (AGC). The investigated system included non-reheat thermal power system in area 1 and 2, while area 3 and 4 are single reheat thermal power system and area 5 and 6 are double reheat thermal power system. All areas are interconnected through tie-line. A Proportional-Integral-Derivative (PID) controller is proposed as a secondary controller to provide the necessary control signal during sudden load demand. To achieve optimal PID controller performance, the controller gain values are optimized by considering nature inspired meta-heuristic algorithm, namely the Ant Colony Optimization (ACO) technique using different objective functions. Time domain specification analysis is considered to evaluate the performance of investigated power system, where the power system is designed and modeled under Matlab/Simulink environment. Finally, simulation results established that Integra Time Absolute Error (ITAE) objective function based PID controller provided superior performance compared to other objective function based PID controller.
Keywords: Automatic generation control, multi-area power systems, objective function, proportional-integral-derivative
DOI: 10.3233/IDT-160275
Journal: Intelligent Decision Technologies, vol. 11, no. 1, pp. 29-38, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]