Article type: Research Article
Authors: Lin, Chia-Hunga; * | Kan, Chung-Dannb | Chen, Wei-Lingc | Mai, Yi-Chend | Chen, Ying-Shina
Affiliations: [a] Department of Electrical Engineering, National Chin-Yi University of Technology, Taichung City, Taiwan | [b] Division of Cardiovascular Surgery, Department of Surgery, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan City, Taiwan | [c] Food and Drug Administration, Ministry of Health and Welfare, Taipei City, Taiwan | [d] Department of Aeronautics and Astronautics, National Cheng Kung University, Tainan City, Taiwan
Correspondence: [*] Corresponding author: Chia-Hung Lin, %****␣idt-15-idt200018_temp.tex␣Line␣25␣**** Department of Electrical Engineering, National Chin-Yi University of Technology, Taichung City, 41170, Taiwan. E-mail: [email protected],[email protected].
Abstract: Extracorporeal membrane oxygenation (ECMO) is employed to treat critical patients for one to a few days of life support in intensive care units. Venovenous (VV) and venoarterial (VA) ECMO configurations are the most commonly used rescue strategies for temporary cardiac and respiratory function support. However, both ECMO modes sometimes cannot meet a patient’s demands because of (a) less oxygenated blood in either the upper body or lower body, or (b) a deterioration in the patient’s hemodynamic status. Veno-Venoarterial (VVA) ECMO is an upgraded system that provides sufficiently oxygenated blood to the systemic and pulmonary circulation systems. Drainage cannulas and gas flow exchanges are determined to provide the maximum drainage blood flow required by the patient through a servo-regulator that adjusts the motor speed. A generalized regression neural network (GRNN) based estimator is created to automatically estimate the desired pump speed and then provide sufficient drainage flow for temporary life support. To achieve stability flow in an ECMO circuit, a bisection approach algorithm (BAA) is employed to improve the performance of transient responses in step controls and steady state controls. Experimental studies are used to validate the proposed model and it is compared with conventional controllers to indicate good performance in clinical VVA ECMO applications.
Keywords: Extracorporeal membrane oxygenation (ECMO), Veno-VenoArterial (VVA), Generalized Regression Neural Network (GRNN), Bisection Approach Algorithm (BAA)
DOI: 10.3233/IDT-200018
Journal: Intelligent Decision Technologies, vol. 15, no. 2, pp. 221-230, 2021
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]