Article type: Research Article
Authors: Xu, Weipinga; b | Nan, Shulianga | Bai, Wenkuna | Shen, Ea | Hu, Binga; *
Affiliations: [a] Department of Ultrasound in Medicine, Shanghai Jiao Tong University Affiliated Sixth People’s Hospital, Shanghai Institute of Ultrasound in Medicine, Shanghai, China | [b] Department of Ultrasound, Shanghai Minhang District Central Hospital of Ruijin Hospital Group, Shanghai, China
Correspondence: [*] Corresponding author: Bing Hu, Department of Ultrasound in Medicine, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai Institute of Ultrasound in Medicine, 600 Yi Shan Road, Shanghai 200233, China. E-mail: [email protected].
Abstract: Background:Caveolin-1 is a major structural component of cell membrane invaginations. Over-expression of caveolin-1 is closely related to the tumorigenesis and progression of prostate cancer. Recently, contrast microbubbles in combination with ultrasound are being investigated for their therapeutic applications in tumor cells. However, the response of caveolin-1 after low-frequency ultrasound and SonoVue treatment in animal model is unclear. Objective:The goal of this study was to evaluate the effect of 80 kHz ultrasound and/or SonoVue on caveolin-1 expression and secretion in DU145 prostate tumors in nude mice. Methods:Six-week-old BALB/c male nude mice were subcutaneously injected with DU145 cells in the right flank to establish a prostate cancer model, which were randomly divided into four groups (n=8 each): control group (sham-ultrasound exposure), SonoVue group, 80 kHz ultrasound group, 80 kHz ultrasound combined with SonoVue group. Tumor volumes and wet weights were measured, and the tumor volume curve was obtained as well. The mice were euthanized 21 days after treatment. Specimens of the tumor tissues were assessed the expression of caveolin-1 by immunohistochemistry and Western blot. The serum concentrations of caveolin-1 were detected by ELISA. Results:Treatment with ultrasound alone produced tumor volumes and weights reduction compared with control and SonoVue group. Combined ultrasound and SonoVue treatment produced greater tumor regression than either treatment alone (p < 0.05). Serum caveolin-1 concentrations were lower in the combination of ultrasound and SonoVue group than they were in control group (p =0.005), and had some certain correlation with tumor growth (wet weight) (r =0.507), although the difference was not statistically significant (p=0.199). Ultrasound alone treatment only slightly reduced the caveolin-1 concentrations in comparison with the control, and the difference was not statistically significant (p=0.125). The ultrasound-treated mice showed significant reduction in expression levels of caveolin-1 protein, compared with the control (p < 0.05). Levels of caveolin-1 were further reduced when combined with ultrasound and SonoVue as compared to the control (p < 0.01). Conclusions:Our results suggest that 80 kHz ultrasound have antitumor effect and the effect could be further strengthened by the combination of SonoVue. Down-regulating the expression of caveolin-1 is likely a potential biomarker of response to ultrasound and SonoVue treatment in prostate cancer mouse model.
Keywords: Prostate cancer, low-frequency ultrasound, SonoVue, caveolin-1, biomarker
DOI: 10.3233/CBM-140405
Journal: Cancer Biomarkers, vol. 14, no. 4, pp. 279-286, 2014
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]