Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Bílý, Petra; * | Fládr, Josefa | Ryjáček, Pavelb | Stančík, Vojtěchb
Affiliations: [a] Department of Concrete and Masonry Structures, Faculty of Civil Engineering, Czech Technical University in Prague, Prague, Czech Republic | [b] Department of Steel and Timber Structures, Faculty of Civil Engineering, Czech Technical University in Prague, Prague, Czech Republic
Correspondence: [*] Corresponding author. Petr Bílý, Department of Concrete and Masonry Structures, Faculty of Civil Engineering, Czech Technical University in Prague, Thákurova 7, 16629 Praha, Prague, Czech Republic. Tel.: +420737431835; E-mail: [email protected].
Abstract: In Europe, a deck of a concrete bridge usually consists of several layers with specialized functions. The concept where all the functions are integrated into one layer (called “unprotected concrete bridge deck – UCBD” in this paper) is popular in the North America. This paper deals with design, construction and monitoring of the pilot UCBD structure in the Czech Republic. Considering the requirements on the structure and the material, polymer fiber reinforced concrete (PFRC) was selected as the most suitable alternative. The composition of the material was optimized during an extensive experimental program. The developed material was then applied on a small-span bridge on a local road. The presented pilot structure is the first of its kind in the Czech Republic and according to the knowledge of the authors, PFRC has not been used for UCBD anywhere else in Europe before. A cost analysis was carried out to estimate the economic efficiency of the solution. Total direct savings reached 5% of the total costs of the project. The pilot structure will be subjected to long-term monitoring with the aim to verify the reliability of the new concept and to perform a more detailed life cycle cost analysis. The results of monitoring after the first year showed satisfactory performance of the structure.
Keywords: Concrete bridge deck, fiber reinforced concrete, polymer fibers, wearing surface, crack width, composite structure
DOI: 10.3233/BRS-200170
Journal: Bridge Structures, vol. 16, no. 1, pp. 15-26, 2020
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]